AMX DXF-TX-MMD Instruction Manual page 109

Amx dxlink fiber transmitters and receivers
Hide thumbs Also See for DXF-TX-MMD:
Table of Contents

Advertisement

Telnet Commands (continued)
FACTORYFWIMAGE
FWIMAGES
GET CONFIG
GET CONNECTION
GET DEVICE
Instruction Manual – DXLink Fiber Transmitters and Receivers
Resets unit to factory firmware image and parameters and reboots the DXLink Fiber unit.
Note: When a Transmitter is connected to a DXLink Fiber Input Board, the input board will
override the "ALL RESOLUTIONS" EDID and load the last stored EDID.
Displays firmware version information.
Displays the current connection settings.
Example:
>get config
Device number: 8010
Connection Settings
--------------------------------
Mode:
NDP
System Number:
3155
Master IP/URL:
192.168.44.53
Master Port:
1319
Username:
Password:
IP Settings
--------------------------------
HostName:
DXLF-TX-2075028
Type:
DHCP
IP Address:
192.168.44.86
Subnet Mask:
255.255.255.0
Gateway IP:
192.168.44.2
MAC Address:
00:0f:3c:00:55:04
DHCP Server
: 192.168.43.2
Lease Origin
: THU 01/09/2031 12:59:02
Lease Duration
: SUN 01/12/2031 12:59:02 (259200 sec)
Lease Renew
(T1): SAT 01/11/2031 00:59:02 (129600 sec)
Lease Rebind (T2): SUN 01/12/2031 03:59:02 (226800 sec)
DNS Servers
--------------------------------
Domain suffix:
amx.internal
Entry 1:
192.168.40.7
Entry 2:
192.168.40.8
Note: The system number and IP addressing information displayed is reflective of actual
operating values, not stored parameters.
Shows the Master connection information.
Example:
>get connection
Connection Settings
------------------------------
Mode:
UDP URL
System Number:
1
Master IP/URL:
192.168.44.53
Master Port:
1319
Username:
Password:
Displays the device number.
Example:
>get device
Device Number
------------------------------------------
Stored Value:
Active Value:
Appendix B – Telnet (Terminal) Commands
0 (dynamic)
32005
109

Advertisement

Table of Contents
loading