Power supply units
6.1.1

Power supply unit configurations

Figure 13: Hot-plug power supply units
Power
Number in
class
figure
1
2
3
I
All different hot-plug power supply units are to install, to remove or to
replace in the same way.
6.1.2

Assembly rules

– Mixed assembly of hot-plug power supply units from different power
classes(e.g. class 1, class 2, or class 3) within a system is not released.
– Mixing of Platinum and Titanium PSU within same class (e.g. class 2) within
a system is not released.
102
Power
1
450 W
1
450 W
2
800 W
3
800 W
4
1200 W
Upgrade and Maintenance Manual
item
Part Number
Platinum
A3C40175929 /
S26113-E575-V53
Platinum
A3C40172099 /
S26113-E575-V70
Platinum
A3C40175928 /
S26113-E574-V53
Titanium
A3C40169522 /
S26113-E615-V50
Platinum
A3C40170546 /
S26113-E616-V50
RX2540 M1