2 - 16 MP6000 INTEGRATOR GUIDE

RS-232 Host Parameters

Various RS-232 hosts use their own parameter default settings. Selecting standard, ICL, Fujitsu,
Wincor-Nixdorf Mode A, Wincor-Nixdorf Mode B, OPOS/JPOS, Olivetti, Omron, Common Use Terminal
Equipment (CUTE-LP/LG bar code readers), NCR, or Datalogic sets the defaults listed in
2-6.
NOTE All items listed in
support scanner and scale.
Terminal Specific RS-232
Table 2-5
Parameter
Baud Rate
Parity
Stop Bit Select
ASCII Format
Hardware Handshaking
Software Handshaking
Serial Response Timeout
RTS Line State
Beep On <BEL>
Transmit Code ID
Data Transmission Format
Prefix
Suffix
In the Nixdorf Mode B, if CTS is low, scanning is disabled. When CTS is high, scanning is enabled.
If you scan Nixdorf Mode B without connecting the digital scanner to the proper host, it may appear
unable to scan. If this happens, scan a different RS-232 host type within 5 seconds of cycling power to the
digital scanner.
Table 2-5
and
Table 2-6
ICL
Fujitsu
9600
9600
Even
None
One
One
8-Bit
8-Bit
RTS/CTS Option 3
None
None
None
9.9 Sec.
2 Sec.
High
Low
Disable
Disable
Yes
Yes
Data/Suffix
Data/Suffix
None
None
CR (1013)
CR (1013)
are for scanner only connections, except for NCR which can
Wincor-Nixdorf
Mode A
9600
Odd
One
8-Bit
RTS/CTS Option 3
None
None
Low
Disable
Yes
Data/Suffix
None
CR (1013)
Table 2-5
and
Table
Wincor-Nixdorf Mode
B/OPOS/JPOS
9600
Odd
One
8-Bit
RTS/CTS Option 3
None
None
Low = No data to send
Disable
Yes
Data/Suffix
None
CR (1013)

Advertisement