Install Sensormatic Coils - Motorola MP6000 Integrator Manual

Motorola mp6000 scanner-scale integrator guide
Hide thumbs Also See for MP6000:
Table of Contents

Advertisement

3 - 34 MP6000 INTEGRATOR GUIDE
To ensure smooth scanning, replace the platter, take a steel can (like a soup can), turn it over so
the harsher seam is facing down, and slide the can over the platter in the standard scanning
direction. The can must not catch on the checkstand or the platter when swept across all sections
of the platter, in the correct direction.
Route all cables through the checkstand as shown in
4.
Connect all cables to the MP6000 and POS, as needed (e.g., scale, Scale Display, Checkpoint antennas,
5.
or Sensormatic coils, POS, CSS, etc.).
Power up the MP6000. Upon power up, the MP6000 verifies that all sub-systems, and auxiliary devices
6.
are operational. If a fault condition exists, an error condition displays on the 7-segment display, and the
startup sequence halts. Power cycling is required after rectifying the problem. (See
Warning Codes on page
If a scale is present, warm-up time for the scale is 15 minutes (assuming room the temperature is
70° F/20° C).
IMPORTANT Most accessories (scale, Scale Display, Checkpoint interlock, Sensormatic coils, Sensormatic

Install Sensormatic Coils

The horizontal antenna is installed below the platter, on the middle housing, affixed to the housing with screws.
The vertical antenna is installed behind the vertical glass, also affixed to the scanner with screws. The coil tail
wires (with connectors) should be properly routed alongside the scanner to which the Sensormatic controller
box lead can connect.To install the Sensormatic coils:
Remove the MP6000 platter.Disconnect power to the MP6000.
1.
Remove the MP6000 tower bezel by squeezing inward on both the left and right sides of the lower part of
2.
the tower bezel, pushing its side snaps to disengage. Slide the tower bezel up and lift out. (See
on page
3-17.)
Vertical Sensormatic
Coil Screw Bosses (#6)
Horizontal Sensormatic
Coil Screw Bosses (#6)
Sensormatic Coil Screw Holes (Platter and Tower Bezel Removed)
Figure 3-43
Install the horizontal coil first:
3.
A-5)
RS-232 cable, CSS, and auxiliary RS-232 scanners) must be installed and connected to the
MP6000 prior to applying power to the MP6000.
Figure
3-3.
General Error and
Figure 3-15