7-6
Symbol DS6607 Product Reference Guide

RS-232 Host Parameters

Various RS-232 hosts are set up with their own parameter default settings
Mode A, Wincor-Nixdorf Mode B, OPOS/JPOS, Olivetti, or Omron sets the defaults listed below.
Parameter
Transmit Code ID
Data Transmission Format
Suffix
Baud Rate
Parity
Hardware Handshaking
Software Handshaking
Serial Response Time-out
Stop Bit Select
ASCII Format
Beep On <BEL>
RTS Line State
Prefix
*In the Nixdorf Mode B, if CTS is Low, scanning is disabled. When CTS is High, the user can scan bar codes.
**If Nixdorf Mode B is scanned without the digital scanner connected to the proper host, it may appear unable to scan. If this happens, scan a different
RS-232 host type within 5 seconds of cycling power to the digital scanner.
Table 7-2. Terminal Specific RS-232
ICL
Fujitsu
Yes
Yes
Data/Suffix
Data/Suffix
CR (1013)
CR (1013)
9600
9600
Even
None
RTS/CTS Option 3 None
None
None
9.9 Sec.
2 Sec.
One
One
8-Bit
8-Bit
Disable
Disable
High
Low
None
None
(Table
7-2). Selecting standard, ICL, Fujitsu, Wincor-Nixdorf
Wincor-Nixdorf
Wincor-Nixdorf
Mode B/OPOS/
Mode A
JPOS
Yes
Yes
Data/Suffix
Data/Suffix
CR (1013)
CR (1013)
9600
9600
Odd
Odd
RTS/CTS
RTS/CTS Option 3
Option 3
None
None
9.9 Sec.
9.9 Sec.
One
One
8-Bit
8-Bit
Disable
Disable
Low
Low = No data to
send
None
None
Olivetti
Omron
Yes
Yes
Prefix/Data/
Data/Suffix
Suffix
ETX (1002)
CR (1013)
9600
9600
Even
None
None
None
Ack/Nak
None
9.9 Sec.
9.9 Sec.
One
One
7-Bit
8-Bit
Disable
Disable
Low
High
STX (1003)
None