Scale Calibration Procedure (Scanner/Scale Configurations Only); Scale Configurations; Identifying Firmware Version - Motorola MP6000 Integrator Manual

Motorola mp6000 scanner-scale integrator guide
Hide thumbs Also See for MP6000:
Table of Contents

Advertisement

4 - 2
MP6000 INTEGRATOR GUIDE

Scale Calibration Procedure (Scanner/Scale Configurations Only)

Follow the steps below to calibrate the scale.
NOTES
1. The 30 second timer, or 90 second timer for Firmware versions before 3.4 (see
Firmware
at the
2. If a Scale Display is unavailable, the internal 7-segment one character display can be used as a
user interface to prompt a user through the steps of the scale calibration procedure.
3. The scale can be calibrated without a Scale Display. However, if a Scale Display is used Enable
Scale Display Configuration (page 4-15) must be scanned to enable the display and its port. The
default Scale Display configuration is: Disabled.
4. The MP6000 scanner/scale must remain powered for a minimum of 15 minutes after a cold power
start prior to performing the calibration procedure.
5. At any time during the calibration process: if the units of measure are modified (e.g., lb to kg), and
a 90 second timeout is completed, the Scale Display flashes CAL and the 7-segment display has a
U14
warning code (indicating Scale Out of Calibration).

Scale Configurations

Scale Configurations
Table 4-2
Single interval 0.01 lb (0.005 kg), without calibration switch (model # ending in -06).
Dual interval 0.005 lb (0.002 kg) minimum verification interval, without calibration switch
(model # ending in -08).
IMPORTANT The MP6000 platter can be removed to see the model number of the scale. The model number is

Identifying Firmware Version

A new Calibration Entry Method is required for Firmware Version 3.4 and later. To determine the firmware
version on the scanner, depress and continue to hold the EAS button. The scanner firmware version number
displays on the internal 7-segment display.
The existing Calibration Entry Method should be used for firmware version prior to firmware version 3.4.
Version), resets after each successful stage of the calibration procedure (not applicable
Step 5 - Calibration Success or Failure
printed on a label affixed to the right side of the bottom bar of the scale's U frame. The last two digits
in the model number define the scale's configuration (see
stage).
Description
Table
Identifying
4-2).

Advertisement

Table of Contents
loading

Table of Contents