LEDs, and Beeper Sequences (Continued)
Table 4-6
7-segment
Scale State
Diagnostic Display
Successfully
Calibration procedure
executing and
semantics removed
exiting a scale
from display.
legal calibration
Cold reset of
No change
scale
Audit Tally -
Repeated scroll:
Press and hold
C###
Scale Zero
button for
greater than
three seconds
when not in a
Calibration
Mode.
In Bootloader
No change
Mode
Scale Error
Scrolls fault code:
u##
LED
(System)
No change
No change
No change
P###
then
Off
Red
(Warning)
SCALE CALIBRATION (MODELS WITH A SCALE ONLY) 4 - 23
Beeper
Sequence
Three short
beeps
No change
except at
Step 5
- Calibration
Success or
Failure
- when
the Scale Zero
button is
pressed three
short beeps
tones sound
None
None
None
Scale
Zero
Optional Scale Display
Button
(LED)
Solid green
Scale is reset either by
on if weight
pressing the Scale Zero
stable after
button, scanning the Scale
reset of
Reset parameter bar code,
scale
or powering the unit OFF
then ON. The seven
segment test will run.
No change
Seven segment test runs
and displays:
00.000 all icons
illuminated for three
seconds
Blank for one second
99.999 all icons
illuminated for three
seconds
Blank for one second
Normal display
No change
Blinks between C### and
P###.
Off
None.
Off
Blinks FAIL or blanks
display with unit icon
showing lb or kg
illuminated.
Display can also blink
CALF if the system was in
a scale legal Calibration
Mode.