The RAID Configuration Utility (RCU) need only be run if a KZPSC controller is
in the system. The controller comes with its own documentation describing the
utility. The controller can operate in several different modes, and the customer
should determine how to customize the disk farm. RCU enables the choices.
Prior to running the utility, you should read the documentation and discuss
which mode the customer wishes. Example 8-5 show how to run RCU.
Place the RAID Configuration Utility floppy in the floppy drive.
Use the set command to turn on the arc_enable environment variable.
Use the initialize command to initialize the system and to make the set
command take effect.
After self-test completes, enter run rcu to identify what programs to run.
The run command defaults to the floppy as the source of the program for
execution so no device need be specified.
-p 1 specifies that PCI1 is to be configured.