18.9.6. Internal and external activation

In this example, partition 1 is switched from internal activation (external perimeter protection) to external activation (completely activated).
The system should have external perimeter protection from 18:00 onwards and a complete activation from 20:00 onwards.
The change from internal to external activation cannot be made without an interruption of <
1 minute
(e.g. 19:59
20:00).
If detectors with the Part Set (P) property are set up for partition 1, you can Menu item in week planner: Use Auto Set to Part Set for
partition 1.
( Installer mode - Detector)
Detector in partition 1 with the property: P
Create data record 2 as detailed in the Auto Set and Auto Unset sections.
Set Y, activation time 18:00, Part Set Y and Partitions 1 - - - .
Set Y, deactivation time 19:59 and Partitions 1 - - - .
Set 18:00
Create data record 3 as detailed in the Auto Set and Auto Unset sections.
Set Y, activation time 20:00, Part Set N and partitions 1 - - - .
Unset time 07:20 on the following day (Tuesday) with data record 1.
Please make sure to use the data record 1 on the next day for deactivation.
There is a danger of losing track of the programming.
Activation Monday, 20:00
(Week Planner)
Part Set: Y for partition 1
Unset 19:59
Select the next day (Tuesday)
Deactivation Tuesday, 07:20
37
Monday
Time
P1
P2
P3
P4
P1
00:00
00:00
01:00
Data record 1
02:00
03:00
S
04:00
05:00
06:00
07:00
07:20
07:20
08:00
09:00
10:00
11:00
12:00
13:00
14:00
15:00
16:00
17:00
18:00
18:00
Data record 2
19:00
P
20:00
19:59
21:00
20:00
Monday
Data record 3
22:00
S
Activation
23:00
00:00
Tuesday
P2
P
Tuesday
Data record 1
Deactivation