Jumpers; Internal Piezo Signaller; Installation Instructions; Installation - Abus CASA10010 Installation Instructions Manual

Ip alarm module
Table of Contents

Advertisement

Available languages
  • EN

Available languages

3.6

Jumpers

The IP alarm module is equipped with three different jumper con-
nections, each of which has a different meaning. These meanings
are as follows:
Kick Start: Not used
Fit Disable: This jumper is positioned above the "O/P Fault" LED.
This jumper must be plugged in if the tamper contact
on the rear is not used.
OP1-OP4: These jumpers are positioned below the cover
tamper contact.
They regulate the output behaviour of the relay. They
must be set to 0 V.
12V
12V
0V
0V
3.7

Internal piezo signaller

The built-in piezo is used to support the programming of the
IP alarm module. See the notes on the respective function. Ad-
ditionally, the piezo can be activated for signal reception during the
detector/function test.
4.

Installation instructions

4.1

Installation

Proceed as follows when installing the IP alarm module:
Determine the best possible installation location. This should be
selected so that good wireless communication between the com-
ponents is guaranteed. We recommend using the wireless testing
box for determining the installation location.
Note: Position the IP alarm module so that it is within the monitored
range of a detector. Make sure that the IP alarm module is installed
as high as possible – at least 1 metre above the ground.
The device must not be installed in the following locations:
- In protected or unprotected outdoor areas
- Within 1 metre of electronic equipment and lines, such as
computers, photocopiers, LAN and high-voltage or three-phase
voltage lines
35