12. Internal activation

In addition to monitoring one or more partitions (i.e. objects or company departments) separately, the system also has an internal activation option. This type of
activation is often used to monitor the exterior of the object when it is still occupied. In this case, specific detectors within the object such as motion sensors are
removed from surveillance. The same authorisations apply for internal activation as for any other activation. That means that only users who are authorised to
activate the entire system can internally activate an area. This also applies to remote controls.

12.1. On the system

Enter your user code or hold your chip key over
the system reader. If you are authorised to
activate more than one partition, the following
graphic display is shown:
Select Part Set All and confirm by pressing
Select.
All areas of the alarm system for which the user
code is authorised are now internally activated.
The system emits the following acoustic
message:
"Alarm system activated internally"
To activate separate partitions internally, select
"Partitions" until the following graphic display is
shown:
Select the partition to be activated.
Change the settings for this partition.
The displayed codes next to the partition have
the following meanings:
Display
Meaning
U
This partition remains deactivated.
U>P
This partition is activated internally.
U>S
This partition is activated.
S>U
This partition is deactivated.
P>U
This partition is deactivated
internally.
S
This partition remains activated.
P
This partition remains activated
internally.
To activate one or more partitions internally,
select U>P next to the corresponding partition.
Confirm your entry by pressing Done.
The system then carries out the entered actions
(activation/deactivation). If only one partition is
internally activated, the system issues the
following message:
"One partition activated internally"
14
12.2. Using the wireless remote
control
Partitions can be activated internally using the
wireless remote control in two ways:
a) The remote control internally activates all
partitions within the user's authorisation.
b) The keys of the remote control unit are
programmed in the user menu to activate
individual partitions internally.
Example of key settings:
1
1) Complete activation
(partitions 1 and 3)
2) Complete deactivation
3
3) System status
4) Complete internal
activation
5) Activate partition
3 internally
2
See also "System Config".
2
4
1
5
4