7.1.3 Analog outputs (Drive Demand/Command - X7)

Description
Type
Output voltage range
Output current (max)
Output DAC resolution
Equivalent resolution
Update interval
7.1.4 Digital inputs (X1 & X2)
Description
Type
Input voltage (Active high)
Input voltage (Active low)
Input current (approximate, per input)
Sampling interval

7.1.5 Digital inputs (X3)

Description
Type
Input voltage (Active high)
Input voltage (Active low)
Input current (approximate, per input)
Sampling interval
7-2 Specifications
Unit
VDC
mA
bits
mV
Unit
VDC
VDC
Nominal
Minimum
VDC
Nominal
Maximum
mA
ms
Unit
VDC
VDC
Nominal
Minimum
VDC
Nominal
Maximum
mA
ms
Value
Bipolar
±10
1
14
(includes sign bit)
±1.22
Immediate
Value
Opto-isolated, AC inputs
24
12
0
2
8
1
Value
Non-isolated, AC inputs
24
12
0
2
8
1
MN1903