4.3.2 Analog outputs (Drive Demand/Command) - X7

MintMT and the Mint Motion Library use the analog outputs to control servo drives.
Demand / Command outputs 0 to 3 correspond to axes 0 to 3. The analog outputs may be
used to drive loads of 10kΩ or greater. The outputs are referenced to PC system ground.
Shielded twisted pair cable should be used. The shield connection should be made at one end
only.
MN1903
Location
12
Pin
1
2
3
1
4
5
6
7
8
9
10
11
12
Description
Four independent command outputs
Output range: ±10VDC (±0.1%).
Resolution: 14-bit (accuracy ±1.22mV).
Output current: 1mA maximum
Update frequency: Immediate
NextMove PCI
10k
Demand
±100%
160k
Figure 2 - Analog output circuit - Demand0 shown
Breakout module, connector X7
Name
Demand0
AGND
Shield
Demand1
AGND
Shield
Demand2
AGND
Shield
Demand
AGND
Shield
10k
-
+
Description
Demand output signal for axis 0
Analog ground
Shield connection
Demand output signal for axis 1
Analog ground
Shield connection
Demand output signal for axis 2
Analog ground
Shield connection
Demand output signal for axis 3
Analog ground
Shield connection
Breakout
module
X7
100
pin
cable
Demand0
1
AGND
2
Input / Output 4-7