Can2 (Baldor Can) - X18 - Baldor NextMove PCI Installation Manual

Motion controller
Table of Contents

Advertisement

4.6.2 CAN2 (Baldor CAN) - X18

Baldor CAN connections are made using the breakout module connector X18.
1
8
If NextMove PCI is at the end of the Baldor CAN network a termination resistor must be
connected by fitting the termination jumper J7, labelled "BC Term", on the breakout module.
4-22 Input / Output
Location Breakout module, connector X18
Pin Name
1 -
2 -
3 -
4 CAN2 0V
5 CAN2 V+
6 -
7 CAN2+
8 CAN2-
Description
Baldor proprietary CAN interface using a RJ45 connector.
Description
(NC)
(NC)
(NC)
Ground/earth reference for CAN signal
CAN remote node power V+ (12-24V)
(NC)
CAN channel 2 positive
CAN channel 2 negative
MN1903

Advertisement

Table of Contents
loading