4.4.4 Digital outputs - X4

Each optically isolated output is designed to source current from the customer supplied
12-24V supply (USR V+) as shown in Figure 5. The use of shielded cable is recommended.
The CGND must be connected to the host PC's GND. See section 4.5.3 for details about
connecting the USR V+ supply.
NextMove PCI
OUTX.6
Figure 5 - Digital output circuit with standard 'PNP' current sourcing module - DOUT6 shown
MN1903
Location Breakout module, connector X4
12
Pin Name
1 Shield
2 DOUT6
3 DOUT7
1
4 DOUT8
5 DOUT9
6 DOUT10
7 DOUT11
8
-
9
-
10 Shield
11 USR V+
12 CGND
Description
Six general purpose optically isolated digital outputs.
Output current: 50mA maximum each output
Update frequency: Immediate
Output
module
MintMT keyword / description
Shield connection
OUTX.6
OUTX.7
OUTX.8
OUTX.9
OUTX.10
OUTX.11
(NC)
(NC)
Shield connection
Customer power supply
Customer power supply ground
Breakout
module
X4
11
100
pin
cable
DOUT6
2
12
USR V+
Output
load
CGND
Input / Output 4-13