Can1 (Canopen) - X17 - Baldor NextMove PCI Installation Manual

Motion controller
Table of Contents

Advertisement

Terminators must only be fitted at both ends of the network, not at intermediate nodes.
H
The 0V connection of all of the nodes on the network must be tied together through the
H
CAN cabling. This ensures that the CAN signal levels transmitted by NextMove PCI or
CAN peripheral devices are within the common mode range of the receiver circuitry of
other nodes on the network.

4.6.1 CAN1 (CANopen) - X17

CANopen connections are made using the breakout module connector X17.
1
6
9
If NextMove PCI is at the end of the CANopen network the termination resistor must be
connected by fitting the termination jumper J8, labelled "CO Term", on the breakout module.
MN1903
Location Breakout module, connector X17
Pin Name
1 Shield
5
2 CAN1-
3 CAN1 GND
4 -
5 -
6 -
7 CAN1+
8 -
9 CAN1 V+
Description
CANopen interface using a 9-pin male D-type connector with CiA
standard DS102 pin configuration
Description
Cable shield
CAN channel 1 negative
CAN1 Ground / earth reference
(NC)
(NC)
(NC)
CAN channel 1 positive
(NC)
CAN1 power (12-24V)
Input / Output 4-21