3.2 Location requirements

It is essential that you read and understand this section before beginning the
installation.
CAUTION: To prevent equipment damage, be certain that input and output signals
CAUTION: To ensure reliable performance of this equipment be certain that all
CAUTION: Avoid locating the NextMove PCI or host PC immediately above or beside
CAUTION: Avoid locating the NextMove PCI or host PC in the vicinity of corrosive
The safe operation of this equipment depends upon its use in the appropriate environment.
The following points must be considered:
The NextMove PCI must be installed in an enclosed cabinet located so that it can only be
H
accessed by service personnel using tools.
The maximum suggested operating altitude is 6560ft (2000m).
H
The NextMove PCI must be installed in an ambient temperature of 32°F to 104°F
H
(0°C to 40°C).
The NextMove PCI must be installed in relative humidity levels of less than 80% for
H
temperatures up to 87°F (31°C) decreasing linearly to 50% relative humidity at 104°F
(40°C) (non-condensing).
The NextMove PCI must be installed where the pollution degree according to IEC664 shall
H
not exceed 2.
Power is supplied to the card from the host PC power supply bus.
H
The atmosphere shall not contain flammable gases or vapors.
H
There shall not be abnormal levels of nuclear radiation or X-rays.
H
3-2 Basic Installation
are powered and referenced correctly.
signals to/from the NextMove PCI are shielded correctly.
heat generating equipment, or directly below water steam pipes.
substances or vapors, metal particles and dust.
MN1903