Real Time Clock
The control panel keeps and displays time and
(RTC)
date. This feature is also used for the log file by
providing the date and time of each event
Battery Test
Once every 10 seconds

E2. Wireless

PowerMaster-10 G2
RF Network
PowerG – 2-way synchronized Frequency
Hopping (TDMA / FHSS)
Frequency bands
433 – 434
(MHz)
Hopping
8
frequencies
Region
Worldwide
Encryption
AES-128
Note: AES-128 bit encryption for
communication between control unit and
initiating devices is not suitable as a means of
Encrypted Line Security in UL Listed product.
* For UL Listed product, enable this frequency band.

E3. Electrical

PowerMaster-10 G2
External AC/AC
Europe: 230VAC 50Hz input, 9VAC 700mA
adaptor
output.
USA: 120VAC 60Hz input, 9VAC 1000mA
output.
External AC/DC
NA
adaptor
Internal AC/DC
Internal switching power supply:
Input: 100-240VAC, 0.12 A Max.
Output: 7.5VDC, 1.2A Max.
Current Drain
Approx. 240 mA standby at the beginning
(power ON) and then goes down to 90 mA
standby, 1200 mA peak at full load.
Low Battery
4.8 V
Threshold
Backup Battery
• 4.8V 1300 mAh, rechargeable NiMH battery
Pack
• 4.8V 1800 mAh, rechargeable NiMH battery
• 4.8V 2200 mAh, rechargeable NiMH battery
Caution! Risk of explosion if battery is
replaced by an incorrect type. Dispose of
used batteries according to the
manufacturer's instructions.
Note: For compliance with CE standards the
battery capacity must be at least 1300 mAh.
D-304829 PowerMaster-10/30 G2 User's Guide
868 - 869
4
Europe
pack, p/n GP130AAM4YMX, manufactured
by GP or p/n LTT-1300AA4Y, manufactured
by LTT.
pack, p/n GP180AAH4YMX, manufactured
by GP or p/n LTT-1800AA4Y, manufactured
by LTT.
pack, p/n GP220AAH4YMX, manufactured
by GP or p/n LTT-2300AA4Y, manufactured
by LTT. For UL Listed product, use these
batteries only.
PowerMaster-30 G2
The control panel keeps and displays time and
date. This feature is also used for the log file by
providing the date and time of each event
Once every 10 seconds
PowerMaster-30 G2
PowerG – 2-way synchronized Frequency
Hopping (TDMA / FHSS)
912 – 919*
433 – 434
50
8
North
Worldwide
America and
selected
countries
AES-128
Note: AES-128 bit encryption for
communication between control unit and
initiating devices is not suitable as a means of
Encrypted Line Security in UL Listed product.
PowerMaster-30 G2
NA
External (wall-mounted) switching power
supply 100VAC to 240VAC, 50/60 Hz, 0.5A /
12.5 VDC, 1.2A
Internal switching power supply:
Input: 100-240VAC, 0.75A
Output: 12.5 VDC, 1.6A.
Approx. 260 mA standby at the beginning
(power ON) and then goes down to 60 mA,,
1400 mA max. current drain during alarm.
7.2 V (6-cell battery pack)
9.6 V (8-cell battery pack)
Backup Battery Options:
Maximum external devices current (1)
1300 mAh
6 Battery
Pack (2)
4h
180 mA
8h
70 mA
12h
35 mA
24h
max
backup w/o
load 22
hours
32h
no backup
39h
no backup
(1) The external devices must be connected
between 12V and ground. The current for
each specified backup period can be
drawn from the batteries with the internal
GSM and the proximity reader connected
to the PowerMaster-30 G2.
APPENDICES
868 - 869
912 – 919*
4
50
Europe
North
America and
selected
countries
1800 mAh
2200 mAh
8-Battery
8-Battery
Pack (3)
Pack (4)
300 mA
380 mA
125 mA
160 mA
70 mA
95 mA
12 mA
25 mA
0 mA
10 mA
no backup
0 mA
69