14.2 Replace the filter (for inlet Ventilation)

Make sure to replace the filter when it is required to keep the air intake clear of dust, and prevent possible over temperature
issue of the projector due to the clog of filter.
C
AUTION: The high density filter must be replaced on a regular basis, depending on the environment
condi- tions of the projector. Suggest to replace filter every 500 hours runtime.
W
ARNING: Switch off the projector and unplug the power cord before starting the procedure.
C
AUTION: Never use the projector with removed filters !
Necessary parts
New filter (available kit : R9899730, contains 2 high density filters)
C
AUTION: Never clean the filter Always replace with a new one.
How to change the filter
1. Loosen the five screws on the projector left side cover.
2. Take out the old filter.
RLM W14 08/20/2014
14.Lamp and Filter Maintenance
73