Cisco Power system Installation Manual page 79

Redundant power system
Table of Contents

Advertisement

Chapter 5
Troubleshooting the Cisco RPS
Error Description:
The temperature inside the Cisco RPS is too hot.
SNMP Trap Issued Upon Error:
ciscoEnvMonRedundantSupplyNotification is generated.
The varbinds included are ciscoEnvMonSupplyStatusDescr and
ciscoEnvMonSupplyState.
The value of ciscoEnvMonSupplyState is a warning.
How to Correct Error:
Console Message Issued Upon Correction of Error:
SNMP Trap Issued Upon Correction of Error:
ciscoEnvMonRedundantSupplyNotification is generated.
The varbinds included are ciscoEnvMonSupplyStatusDescr and
ciscoEnvMonSupplyState.
The value of ciscoEnvMonSupplyState is a warning.
OL-3654-01
Error Messages on Cisco 2600 Series and Cisco 3620, Cisco 3640, and Cisco 3725 Routers
Check the temperature of the room where the Cisco RPS is located, and
correct the temperature setting if it is above 40
Check the front and rear panels of the Cisco RPS to make sure they are clear
of any obstructions.
If the error message persists, replace the Cisco RPS.
When an external device console screen displays the Cisco IOS software
prompt (routername> or routername#)
Redundant Power Supply THERMAL condition is now normal
When an external device console screen displays the ROMMON prompt
(
), no console message is issued when the error is corrected.
rommon#>
Cisco Redundant Power System Hardware Installation Guide
o
C.
5-11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rps

Table of Contents