Cisco Power system Installation Manual page 76

Redundant power system
Table of Contents

Advertisement

Error Messages on Cisco 2600 Series and Cisco 3620, Cisco 3640, and Cisco 3725 Routers
Console Error Message:
Error Description:
One of the AC modules has been turned off or has been disconnected or has failed.
See
seconds. If the condition still exists, the error message reappears.
SNMP Trap Issued Upon Error:
ciscoEnvMonRedundantSupplyNotification is generated.
The varbinds included are ciscoEnvMonSupplyStatusDescr and
ciscoEnvMonSupplyState.
The value of ciscoEnvMonSupplyState is a warning.
How to Correct Error:
Check the AC LEDs on the Cisco RPS to determine which AC module is reporting
the error, and try the corrective actions described in
Console Message Issued Upon Correction of Error:
Cisco Redundant Power System Hardware Installation Guide
5-8
When an external device console monitor screen displays the Cisco IOS
software prompt (
routername>
System detected Redundant Power Supply AC FAIL condition.
The Cisco IOS software checks the condition every 30 seconds. If the
condition still exists, the error message reappears.
When an external device console monitor screen displays the ROMMON
prompt (
)
rommon#>
*** System Environmental Interrupt ***
WARNING: REDUNDANT POWER SUPPLY AC FAIL BIT IS ASSERTED.
Table 5-1
for details. The Cisco IOS software checks the condition every 30
When an external device console monitor screen displays the Cisco IOS
software prompt (
routername>
Redundant Power Supply AC condition is now normal.
When an external device console monitor screen displays the ROMMON
prompt (
), no console message is issued when the error is corrected.
rommon#>
Chapter 5
Troubleshooting the Cisco RPS
or
)
routername#
Table
or
)
routername#
5-1.
OL-3654-01