Routers; Dc Failure; Error Messages On Cisco 2600 Series And Cisco 3620, Cisco 3640, And Cisco 3725 Routers - Cisco Power system Installation Manual

Redundant power system
Table of Contents

Advertisement

Error Messages on Cisco 2600 Series and Cisco 3620, Cisco 3640, and Cisco 3725 Routers

Error Messages on Cisco 2600 Series and Cisco 3620,
Cisco 3640, and Cisco 3725 Routers

DC Failure

Note
Cisco Redundant Power System Hardware Installation Guide
5-6
When a Cisco RPS status failure is detected while connected to Cisco 2600 series,
Cisco 3620, Cisco 3640, and Cisco 3725 routers, Cisco IOS software receives an
interrupt and displays the error messages on the router console. The following
sections describe the console messages and SNMP traps issued following each
error condition and after corrective action.
LED status:
DC LED 1, 2, 3, or 4 is amber.
The DC LED is always amber for 10 to 15 seconds after the DC output module
has been connected and the external device has been powered on.
Console Error Message:
When an external device console monitor screen displays the Cisco IOS
software prompt (
System detected Redundant Power Supply DC FAIL condition.
The Cisco IOS software checks the condition once every 30 seconds. If the
condition still exists, the error message reappears.
When an external device console monitor screen displays the ROMMON
prompt (
rommon#>
*** System Environmental Interrupt ***
WARNING: REDUNDANT POWER SUPPLY DC FAIL BIT IS ASSERTED.
Error Description:
The cable connected to one of the internal DC output modules is loose, or one of
the internal DC output modules in the Cisco RPS has failed.
or
routername>
routername#
)
Chapter 5
Troubleshooting the Cisco RPS
)
OL-3654-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rps

Table of Contents