Temperature Error - Cisco Power system Installation Manual

Redundant power system
Table of Contents

Advertisement

Error Messages on Cisco 2600 Series and Cisco 3620, Cisco 3640, and Cisco 3725 Routers

Temperature Error

Cisco Redundant Power System Hardware Installation Guide
5-10
How to Correct Error:
The Cisco RPS continues to operate with a single fan failure, but to correct the
failure, replace the Cisco RPS.
Console Message Issued Upon Correction of Error:
When an external device console monitor screen displays the Cisco IOS
software prompt (
Redundant Power Supply THERMAL condition is now normal.
When an external device console screen displays the ROMMON prompt
(
), no console message is issued when the error is corrected.
rommon#>
SNMP Trap Issued Upon Correction of Error:
ciscoEnvMonRedundantSupplyNotification is generated.
The varbinds included are ciscoEnvMonSupplyStatusDescr and
ciscoEnvMonSupplyState.
The value of ciscoEnvMonSupplyState is a warning.
LED status:
TEMP LED is amber.
Console Error Message:
When an external device console monitor screen displays the Cisco IOS
software prompt (
System detected Redundant Power Supply THERMAL FAIL condition.
The Cisco IOS software checks the condition once every 30 seconds. If the
condition still exists, the error message reappears.
When an external device console screen displays the ROMMON prompt
(
)
rommon#>
*** System Environmental Interrupt ***
WARNING: REDUNDANT POWER SUPPLY THERMAL BIT IS ASSERTED.
or
routername>
routername#
or
routername>
routername#
Chapter 5
Troubleshooting the Cisco RPS
)
)
OL-3654-01