Carrier 58MXA Installation, Start-Up, And Operating Instructions Manual page 8

Deluxe 4-way multipoise fixed-capacity direct vent condensing gas furnace sizes 040o140, series 170
Table of Contents

Advertisement

PLUG
COLLECTOR
DRAIN
TUBE
(BLUE
& WHITE
STRIPED)
COLLECTOR
TUBE
(PINK)
COLLECTOR
BOX
"-_
TUBE
(GREEN)
INDUCER
(MOLDED)
DRAIN
TUBE
(BEHIND
COLLECTOR
BOX
DRAIN
TUBE)
DRAIN
TUBE
(BLUE)
FACTORY-SUPPLIED
DRAIN
TUBE
COUPLING
(LEFT
DRAIN
OPTION)
PLUG
CAP
COLLECTOR
BOX
DRAIN
TUBE
(BLUE
& WHITE
STRIPED)
COLLECTOR
BOX
TUBE
(PINK)
COLLECTOR
BOX --
TUBE (GREEN)
COLLECTOR
BOX
--
DRAIN
TUBE
(BLUE)
CONDENSATE
_
TRAP
EL
INDUCER
J
HOUSING
DRAIN
TUBE
(VIOLET)
©
O O
FIELD-INSTALLED
FACTORY-SUPPLIED
DRAIN
TUBE
FIELD-INSTALLED
FACTORY-SUPPLIED
_i2-1N
CPVC
STREET
ELBOWS
(2) FOR
LEFT
DRAIN
OPTION
FIELD-INSTALLED
FACTORY-SUPPLIED
DRAIN
TUBE
COUPLING
(RIGHT
DRAIN
OPTION)
A94163
Fig. 6--Factory-Shipped
Upflow Tube
Configuration
(Shown
w{th BNower Access
Panel
Removed}
CONDENSATE
TRAP FREEZE
PROTECTION
Ref?r
to Condensate
Drain
Protection
section
%r recommenda°
lions
and procedures.
Step 3--Downfiow
Applications
A downflow _/mace application is where :_trnace blower is located
above congbustion and controls section of fi_rnace, and conditioned
air is discharged downwards
( ONDENSATE
TRAP LO(ATION
The condensate
tlap
mttst be removed
from
the factow-installed
blower
shelf location
and relocated
in selected
application
location
as shown
in Fig. 2, 8, or 9
To relocate
condensate
trap from
the
blower
shelf
to desired
location,
perform
the following:
1. Remove
3 robes connected
to condensate
trap
2. Remove
tlap fiom blower
shelf by gently
pushing
tabs inward
and rotating
trap
3. Remove
casing hole filler cap from casing hole. (See Fig. 2, 8,
or 9.)
4. [nstall casing
hole filler cap into blower
shelf hole where trap
was removed
-->
A94164
Fig. 7--ARernate
Upflow
Configuration
and Trap
Location
CARBON
MONOXIDE
POISONING
HAZARD
Failm'e to follow
this warning
could
result in personal
inju W
or death,
Casing
hole filler cap must
be installed
in blower
shelf hole
when
condensate
trap
is relocated
to prevent
combustion
products
being
drawn
in from
appliances
in the equipment
roonl.
5. [nstall condensate trap into desired casing hole by inserting
robe connection stubs through casing hole and rotating until
tabs snap into locking position,
CONDENSATE
TRAP TUBING
NOTE:
See Fig 8 or 9 or tube routing label on main f:umace door
to check for proper connections,
Relocate robes as described below,
1. Collector Box Drain Tube
a. Remove factory=installed plug from LOWER collector box
drain robe (blue and white striped label),
b. Install removed clamp and plug into UPPER collector box
&ain robe (blue label) which was connected to condensate
t_ap.
c (onnect
LOWER collector box drain connection to con=
densate trap.
(i)
(ondensate
Trap Located on Left Side of (asing
(a) (onnect
LOWER collector box &ain robe (blue
and white striped 1abel) to condensate trap. Tube
does not need to be cut.
(b) Clamp tube to prevent any condensate leakage.