2. Inducer Housing Drain Tube
a Remove and discard LOWER ( molded) inducer housing
drain t ube which w as previously connected
tocondensate
trap.
b.Use inducer housing &ain extension
tube (violet label and
fhctoD--supplied
inloose p arts b ag) t oconnect LOWER
inducer housing &ain connection
tothe condensate
trap
c.Determine
appropriate
length, cut, a nd connect robe.
d.(lamp robe t oprevent any condensate
leakage.
3.Relief Port T ube
a.Extend collector boxrobe (green label) which w as previ=
ously c onnected
tothe condensate
trap bysplicing tosmall
diameter
robe (fhctory=supplied
inloose p arts b ag).
b.Route e xtended
collector boxpressure
robe torelief p ort
connection
onthe condensate
trap.
c.Determine
appropriate
length, cut, a nd connect robe.
d.Clamp r obe t oprevent any condensate
leakage.
CONDENSATE
TRAP FIELD DRAIN ATTACHMENTS
Refer t o Condensate
Drainsection fbr recommendations
and
procedures.
PRESSURE
SWIT(H TUBING
The LOWER c ollector boxpressure
tube (pink label) is fhctory
connected
tothe
pressure
switch
for use when
Ihrnace
is installed
in UPFLOW
applications.
This
robe
MUST
be
disconnected,
extended,
rerouted,
and then reconnected
to the pressure
switch
in
HORIZONTAL
LEFT
applications.
NOTE:
See Fig. 10 or tube routing
label on main Nrnace
door to
check
for proper
connections.
Modif}" robe as described
below.
1. Disconnect
collector
box pressure
tube (pink label) attached
to
pressure
switch.
2. Use
smaller
diameter
tube
(factov-supplied
in loose
parts
bag) to extend
robe disconnected
in item
1.
3. Route
extended
robe:
a. Behind
inducer
housing,
b. Between
blowe*
shelf" and inducer
housing.
c. Behind
inducer
motor bracket.
d. Between
inducer
motor and pressure
switch.
4. Detem_ine
appropriate
length,
cut,
and
reconnect
robe
to
pressure
switch
connection
labeled
COLLECTOR
BOX.
CONDENSATE
TRAP
FREEZE
PROTECTION
Refer
to Condensate
Drain
Protection
section
for recommenda°
tions and procedures.
CONSTRU(T
A WORKING
PLATFORM
Construct
working
platfbrm
where
all required
Ihrnace
clearances
are met, (See Fig. 3 and 11.)
[TNIT MAY
NOT
OPERATE
Failure
to %llow
this caution
may result
in intem_ittent
unit
operation.
The condensate
trap MUST
be installed
below
furnace
See
Fig
5 ibr dimensions.
The drain
connection
to condensate
trap must also be properly
sloped
to an open
&ain.
NOTE:
Combustion-air
and vent pipes are restricted
to a mini°
mum length
of 5 it. (See Table
7.)
--€
11
NOTE:
A 12-in
mininmm
of_ket pipe
section
is recommended
with
short
(5 to 8 It) vent
systems.
This recommendation
is to
reduce
excessive
condensate
droplets
fiom
exiting
the vent pipe,
(See Fig
11 or 34)
Step
5--Horizontal
Right
{Supply-Air
Discharge)
Applications
A horizontal
right furnace
application
is where
furnace
blowei
is
located
to the left of combustion
and contlols
section
of ihmace,
and conditioned
air is discharged
to the right.
PROPERTY
DAMAGE
Failure
to ibllow
this caution
may result
in minor
property
damage
Local codes may require
a drain pan under entire Ihrnace
and
condensate
trap when
a condensing
fhrnace
is used
in attic
application
or over
a finished
ceiling.
NOTE:
In Canada,
installations
shall
be
in accordance
with
cun'ent
NS(NGPI(
Installation
Codes
and/or
local codes
NOTE:
The junction
box (J-Box)
MUST
be relocated
to opposite
side of furnace
casing.
(See
Fig.
12.) See Electrical
Connection
section
for J-Box relocation.
CONDENSATE
TRAP
LOCATION
The condensate
trap must be removed
fi'om the fi_ctory°installed
blower
shelf location
and relocated
in selected
application
location
as shown
in Fig. 2 or 12,
To relocate
condensate
trap
fiom
the blowei
shelf
to desired
location,
perfbnn
the following:
1
Remove
3 tubes connected
to condensate
nap.
2. Remove
trap from blower
shetfby
gently
pushing
tabs inward
and rotating
trap.
3. Install
casing
hole filler
cap (ihctory=supplied
in loose parts
bag) into blower
shelf hole where
trap was removed.
CARBON
MONOXIDE
POISONING
HAZARD
Failure
to follow
this warning
coutd result
in personal
inju W
or death.
Casing
hole filler cap must
be installed
in blower
shelf" hole
when
condensate
trap
is relocated
to prevent
combustion
products
being
drawn
in from
appliances
in the equipment
roonl.
4. Install
condensate
trap
into
left=hand
side
casing
hole
by
inserting
tube
connection
stubs
through
casing
hole
and
rotating
until tabs snap into locking
position.
5
Fill unused
condensate
tlap
casing
holes
with
plastic
filler
caps (Pactory=supplied
in loose parts
bag).
CONDENSATE
TRAP
TUBING
NOTE:
See Fig. 12 or robe routing
label on main Ihrnace
door to
check
for proper
connections
1
Collector
Box Drain
Tube
a
Remove
factory-installed
plug from LOWER
collector
box
drain robe (blue and white
striped
label).
b
Install
removed
clamp
and plug into UPPER
collector
box
drain tube (blue label) which
was previously
connected
to
condensate
trap.
c
Connect
LOWER
collector
box drain tube (blue and white
striped
label) to condensate
trap
Tube does not need to be
cut,