Carrier 58MXA Installation, Start-Up, And Operating Instructions Manual page 10

Deluxe 4-way multipoise fixed-capacity direct vent condensing gas furnace sizes 040o140, series 170
Table of Contents

Advertisement

PLUG
AUXILIARY
'U" BOX
COLLECTOR
BOX
DRAIN TUBE
(BLUE AND WHITE STRIPED)
O
o
CONDENSATE
TRAP
COLLECTOR BOX
TUBE (GREEN)
BOX EXTENSION
DRAtNTUBE
COLLECTOR
BOX
EXTENSION
TUBE
HOUSING
DRAIN TUBE (VIOLET)
BOX
DRAIN TUBE (BLUE)
DRAIN TUBE COUPLING
COLLECTOR
BOX TUBE (PINK)
RELOCATE TUBE BETWEEN BLOWER SHELF AND INDUCER HOUSING FOR
040,060,
AND 080 HEATING INPUT FURNACES
A00215
Fig. 10--Horizontal
Left Tube Configuration
3. (onnect
collector
box pressure
robe (green
label) to pressure
switch
connection
labeled
COLLECTOR
BOX
4. Extend
collector
box
pressure
tube (pink
label)
which
was
previously
connected
to pressure
switch by splicing
to remain°
lug small diameter
robe (factoQ'-supplied
in loose parts bag).
5. Route this extended
robe (pink label) to condensate
t_ap relief
port connection.
6. Determine
appropriate
length,
cut, and connect
robe.
7. Clamp robe to relief port connection.
CONDENSATE
TRAP FREEZE
PROTECTION
Refkr
to Condensate
Drain
Protection
section
for recommenda°
tions
and procedures.
Step
4--Horizontal
Left {Supply-Ak
Discharge)
Applications
A horizontal
lef[ _mlace
application
is where
furnace
blower
is
located
to the right of combustion
and controls
section
of furnace,
and conditioned
air is discharged
to the le_L
( ONDENSATE
TRAP LO(ATION
The condensate
tlap
must be removed
from
the factor-installed
blower
shelf location
and relocated
in selected
application
location
as shown
in Fig. 2 or 10.
To relocate
condensate
trap from
the
blower
shelf
to desired
location,
perfom_
the fbllowing:
1. Remove
3 robes connected
to condensate
trap
2. Remove
trap fi'om blower
shelf by gently
pushing
tabs inward
and rotating
trap
3. Instal!
casing
hole tiller
cap (factory-supplied
in loose
parts
bag) into blower
shelf hole where
trap was removed.
-->
10
CARBON
MONOXIDE
POISONING
HAZARD
Failure
to follow
this warning
could
result in personal
injury
or death.
Casing
hole filler cap must
be installed
in blower
shelf hole
when
condensate
trap
is relocated
to prevent
combustion
products
being
drawn
in from
appliances
in the equipment
roonl.
4. [nstall
condensate
trap
into
left-hand
side
casing
hole
by
inserting
robe
connection
stubs
through
casing
hole
and
rotating
until tabs snap into locking
position.
5. Fill unused
condensate
trap casing
holes
with
plastic
filler
caps di_ctory-supplied
in loose parts
bag).
CONDEXSATE
TRAP
TUBING
NOTI:::
See Fig. 10 or tube routing
label on main furnace
door to
check
for proper
connections.
1. Collector
Box Drain
Tube
a. Install
&ain tube coupling
(_itctory-supplied
in loose parts
bag)
into collector
box drain
robe (blue
label) which
was
previously
connected
to condensate
trap
b. Connect
large
diameter
drain
robe
and
clamp
(factory-
supplied
in loose parts bag) to drain robe coupling,
extend-
ing collector
box &ain robe.
c. Route extended
tube (blue label) to condensate
trap and cut
to appropriate
length.
d. Clamp
robe to prevent
any condensate
leakage.