Continuous Blower Mode; Heat Pump Mode; Component Test - Carrier 58MXA Installation, Start-Up, And Operating Instructions Manual

Deluxe 4-way multipoise fixed-capacity direct vent condensing gas furnace sizes 040o140, series 170
Table of Contents

Advertisement

The cooling operation described in item 2 above also applies
to operation with a Tl"_ermidistat The exceptions
are listed
below:
a. When the R to G-and-Y1 circuit is closed and there is a
demand fbr dehumidification,
the furnace blower motor
BLWM will continue running at low-cool
speed (same
speed as FAN).
b. When the R to G-and Y/Y2 circuit is closed and there is a
demand for dehumidification,
the furnace blower motor
BLWM will drop the blower speed flora COOL to HEAT
fbr a maximum
of i0 minutes before reverting back to
(OOL speed. If there is still a demand h_r dehumidification
after 20 minutes, the furnace control CPI_ will drop tl-_e
blower speed back to HEAT speed. This alternating
10-
minute cycle will continue as tong as there is a call for
cooling.
c. When the "call for cooling" is satisfied while there is a
demand for dehumidification,
the cooling blower-off delay
is decreased fi'om 90 seconds to 5 seconds,
CONTIN/OUS
BLOWER MODE
When the R to G circuit is closed by the thermostat, the blower
motor BLWM will operate on continuous-blower
speed (can
be adjusted to FAN, HEAT, or COOL speed) at the tl",ermo-
star. Factory- default
is FAN" speed.
Tem_inal EAC-1 is
energized as long as the blower motor BLWM is energized
During a call fbr heat, the blower BLWM will stop during
igniter warn>up
(17 seconds),
ignition
(7 seconds),
and
blower-ON delay (66 or 45 seconds for 040 through 120 sizes
or fbr 140 size), allowing the fiu'nace heat exchangers to heat
up more quickly, then restarts at the end of the blower-ON
delay period at HEAT speed.
In heating, the filmace control CPU will hold the blower
motor BLWM at HEAT speed during the selected blower-OFF
delay period before reverting to continuous-blower
speed.
When the thermostat "calls h_r tow-cooling", the blower motor
BLWM will switch to operate at tow-cool speed (same speed
as FAN) When the them_ostat is satisfied, the blower motor
BLWM will operate an additional 90 seconds on lmv-coot
speed
(same
speed
as FAN) befbre
reve*ting
back
to
continuous-blower
speed
When the thermostat
"calls for high-cooling",
the blowe*
motor BLWM will operate at COOL speed. When the the*-
mostat is satisfied, the blower motor BLWM will operate an
additional 90 seconds on (OOL
speed before reverting back
to continuous-blower
speed
When the R to G circuit is opened, the blower motor BLWM
will continue operating for an additional 5 seconds, if'no other
fhnction requires blower motor BLWM operation
Continuous
Blower Speed Selection from Thermostat
-To
select different
continuous-blower
speeds
from the room
thermostat,
momentarily
trim off the FAN' switch or push-
button on the room thermostat for 1-3 seconds are*" the blower
motor BLWM is operating. The fhmace control CPU will shift
the continuous=blower speed fi'om the fi_ctoW setting of FAN
to HEAT speed. Momentarily
turning off the FAN" switch
again at the thermostat will shik the continuous-blower
speed
fi'om HEAT to COOL. Repeating the procedure will shift the
continuous-blower
speed fi'om COOL back to FAN" speed.
The selection can be changed as many times as desired and is
stored in the memoD" to be automatically
used following a
power inten'uption.
41
HEAT
PUMP
MODE
(See Fig. 52, 53, 54, and 55 %r them_ostat
connections)
When
installed
with a heat pump,
the furnace
control
auto-
matically
changes
the blower
timing
sequence
to avoid
long
blower
ofttimes
during
demand
defrost
cycles
When the R to
W-and-Y
1 or R to W-and-Y
l-and-G
circuits
are energized
the
fhmace
control
(PU
will
switch
to or mrn
on the blower
motor BLWM
at HEAT
speed, and begin a heating
cycle
The
blower
motor
BLWM
wilt remain
on until
the
end of the
prepurge
period,
then shut off for 24 seconds
_hen come back
on at HEAT
speed
When
tl_e W input signal disappears,
the
fimaace control begins
a normal
inducer
post-purge
period
and
the blower
remains
rmming
at HEAT
speed
fPr the selected
blower-OFF
delay
period
then
switches
to low-cool
speed
(same
speed
as FAN)
If the R to W-and-Yl-and-G
signals
disappear
at tl-_e same
time,
the blower
motor
BLWM
will
remain
on fbr the selected
blower-OFF
delay period.
If the R
to W-and-Y1
signals
disappear,
leaving
the
G signal,
the
blower
motor BLWM
will remain
on for the selected
blower-
OFF delay period
then switch
to continuous-blower
speed.
When the R to W-and-Y/Y2,
R to W-and-Y
Y2-and-G,
R to
W-and-Yl-and-YY2,
or R to W-and-Yl-and-YiY2-and-G
circuits
are energized
the hm_ace
control
(PU
will switch to
or mm
on the blower
motor
BLWM
at HEAT
speed,
and
begin
a heating
cycle
The blower
motor BLWM
will remain
on until the end of the prepurge
period,
then shut off for 24
seconds
then come back on at HEAT speed. When the W input
signal disappears,
the fi/mace
contIol begins
a normal
inducer
post-purge
period
and the blower
switches
to COOL
speed
after a 3-second
delay. If the R to W-and-YiY2-and-G
or R to
W-and-Yl-and-YY2-and-G
signals
disappear
at the
same
time, the blower
motor BLWM
will remain
on fbr the selected
blower-OFF
delay
period.
If the R to W-and-YY2
or R to
W-and-Yl-and-Y
Y2 signals
disappear,
leaving
the G signal,
the blower
motor
BLWM
will remain
on for the
selected
blower-OFF
delay
period
then
switch
to continuous-blower
speed.
COMPONENT
TEST
NOTE:
The furnace
contlol
component
test allows
all compo-
nents to run fbr a short time; except
the gas valve
and humidifier
terminal
HUM
are not energized
fbr safety
reasons.
The EA(-I
terminal
is energized
when
the blower
is energized.
This fkature
helps diagnose
a system
problem
in case of a component
fitilure.
The component
test feature
will not operate
if any
thermostat
signal
is present
ant the control
and not until all time delays
are
completed.
To Begin Component
Self=Test:
ELECTRICAL
SHOCK
HAZARD
Failure
to fbllow
this warning
could result in electrical
shock,
personal i_.imy,
or death.
Blower
access
panel
door
switch
opens
l15-v
power
to
control.
No component
operation
can occur. Caution
must be
taken when manually
closing this switch fPr service purposes.
1. Remove
blower
access
door.
2. Disconnect
the thermostat
R lead f?om furnace
control.
3. Manually
close blower
door switch.
4. For approximately
2 sec, short (lumper)
the Cox_-24v tem_inal
on contlol
to the TEST/TWIN
3/16-inch
quick-connect
termi-
nal on control
until the LED goes oftl Remover
jumper
from
terminals.
(See Fig. 3!.)