Carrier 58MXA Installation, Start-Up, And Operating Instructions Manual page 32

Deluxe 4-way multipoise fixed-capacity direct vent condensing gas furnace sizes 040o140, series 170
Table of Contents

Advertisement

TaNe
7--Maximum
Allowable
Pipe Length
(ft) (Continued)
ALTITUDE
(FT}
800t to 9000@
ALTITUDE
(FT)
9001 to I0,000_
UNiT SBZE
040-08
040-I2
060-08
060-12
060-16
080-I2
080-16
080-20
100-16
100-20
120-20
140-20
UNIT SIZE
040-08
040-12
060-08
060-12
060-16
080-12
080-16
080-20
100-16
100-20
120-20
140-20
TERMINATBON
TYPE
2 Pipe or 2-in
Concentric
2 Pipe or 2-in
Concentric
2 Pipe or 2-in
Concentric
2 Pipe or 3-in
Concentric
2 Pipe or 3-in.
Concentric
TERMINATION
TYPE
2 Pipe or 2-in
Concentric
2 Pipe or 2-in
Concentric
2 Pipe or 2-in
Concentric
2 Pipe or 3-in
Concentric
2 Pipe or 3-in.
Concentric
PIPE DmA
NUMBER OF 90 ° ELBOWS
(IN.)*
1
2
3
4
5
6
1-1/2
46
41
36
31
29
24
2
62
60
58
56
55
53
1-1/2
11
6
NA
NA
NA
NA
2
49
44
42
37
35
34
2
33
28
17
12
10
NA
2-1/2
62
60
58
56
55
53
2-1/2
23
15
7
5
NA
NA
3
59
54
49
44
39
34
31- no disk
10
NA
NA
NA
NA
NA
41- no disk
35
30
25
20
15
10
NA
PiPE DtA
NUMBER OF 90 ° ELBOWS
(IN.)*
1
2
3
4
5
1-1/2
42
37
32
27
25
2
57
55
53
51
49
6
2O
47
45
40
38
33
31
29
2
30
25
14
9
7
NA
2-1/2
57
55
53
51
49
47
2-1/2
21
13
5
NA
NA
NA
3
54
49
44
39
34
29
4t no disk
10
5
NA
NA
NA
NA
NA
Disk usage-Unless
otherwise
specified,
use perforated
disk assembly
(factory-supplied
in loose parts bag). If one disk is stated, separate 2 halves of perforated
disk
assembly and use shouldered
disk half When using shouldered
disk half, install screen side toward iNet box.
tWide
radius elbow
SVent sizing for Canadian
installations
over 4500 ft (1370 m) above sea level are subject to acceptance
by the local authorities
having judsdiction.
NA-Not Allowed;
pressure switch will not make.
NOTES:
1 Do not use pipe size greater than those specified
in table or incomplete
combustion,
flame disturbance,
or flame sense lockout may occur
2 Size both the combustion-air
and vent pipe independently,
then use the larger diameter for both pipes
3 Assume two 45 ° elbows
equal one 90 ° elbow
Long radius elbows
are desirable
and may be required in some cases
4 Elbows and pipe sections within the furnace casing and at the vent termination
should not be included
in vent length or elbow count.
5 The minimum
pipe length is 5 ft for all applications
6 Use 3-in. diameter
vent termination
kit for instNlations
requiring 4-in diameter
pipe.
AIR AND VENT
8 314" FOR 3" KIT
6 314" FOR 2" KIT
MAINTAIN
12 IN.
CLEARANCE
ABOVE
HIGHEST
ANTICIPATED
SNOW LEVEL.
MAXIMUM
OF 24 IN. ABOVE
ROOF.
A87224
Fig. 36--Roof
Termination
(Preferred)
e, Termination kit should be positioned where vent vapors are
3, Loosely assemble concentric vent air termination components
not objectionable
together using instructions in kit
2, Cut one 4-in, diameter hole for 2-in, kit, or one 5-in, diameter
4, Slide assembled kit with rain shield REMOVED through hole,
hole for 3-in, kit,
32