Filter Arrangement - Carrier 58MXA Installation, Start-Up, And Operating Instructions Manual

Deluxe 4-way multipoise fixed-capacity direct vent condensing gas furnace sizes 040o140, series 170
Table of Contents

Advertisement

ANGLE
IRON OR
EQUIVALENT
3/8-1N.ROD
ALTERNATE SUPPORT
LOCATION 4-IN. MIN
8-IN. MAX
(B)
(A) ROD LOCATION
USING DIMPLE
LOCATORS
(SEE DIMENSIONAL
DWG FOR
LOCATIONS)
3/8-1N. HEX
& WASHER (4)
REQD PER ROD
(B)
ALTERNATE SUPPORT
LOCATION FROM BACK
(A) PREFERRED ROD LOCATION
(B) ALTERNATE ROD LOCATION
NOTES:
1. A 1 In. clearance minimum between top of
furnace and combustible material.
2. The entire length of furnace must be
supported when furnace is used in horizontal
position to ensure proper drainage.
Fig. 22--Crawlspace
Horizonta{
ApNication
A93304
Step
5--Filter
Arrangement
FIRE,
CARBON
MONOXIDE
AND POISONING
HAZARD
Failure
to %llow
this warning
co_dd result
in fire_ personal
injur?% or death
Never
operate
fi/rnace
without
a filter
or with
filter
access
door removed.
The air filter
an'angement
will va N" due to application,
furnace
orientation,
and
filter
type.
The
filter
may
be
installed
in an
external
Filter/Media
cabinet
(if provided)
or the t'umace
blower
compartment.
Facto_
supplied
washable
filters
are shipped
in the
blower
compartment.
If a factoryosupplied
external
Filter Media
cabinet
is provided,
instructions
for
its application,
assembly,
and
installation
are
packaged
with the cabinet.
The Filter/Media
cabinet
can be used
with
the fitctoryosupplied
washable
filter
or a factor'-specified
highoefficiency
disposable
filter (see cabinet
instructions)
If installing
the filter
in the t_urnace blower
compartment,
deter-
mine
location
%r
filter
and
relocate
filter
retaining
wire,
if
necessary.
See Table 2 to determine
correct
filter size for desired
filter location.
Table
2 indicates
filter
size, location,
and quantity
shipped
with
this
filrnace.
See Fig.
2 %r location
and size
of
bottom
and side returnoair
openings.
18
(IT
HAZARD
Failure
to %llow
this caution
may result
in minor
personal
ir!iury
Use care when cutting
support rods in filters to protect
against
flying pieces and sharp rod ends. Wear
safety glasses,
gloves,
and appropriate
protective
clothing.
[TNIT MAY
NOT
OPERATE
Failure
to fc4tow this caution
may result
in intem_ittent
unit
operation.
For airflow
requirements
above
1800 CFM,
see Air Deliver-
table in Prodnct
Data literature
%r specific
use of single side
inlets
The use of both side inlets, a combination
of 1 side and
the bottom,
or the bottom
only will ensure
adequate
return air
openings
for airflow
requirements
above
1800 CFM.
NOTE:
Side remrnoair
openings
can ONLY
be used in UPFLOW
configurations.
Install
filter(s)
as shown
in
Fig
23
Bottom
return-air
opening
may be used with all 4 orientations.
Filter may
need to be cut to fit some furnace
widths.
Install
filter as shown
in
Fig. 24.
NOTE:
Remove
and discard
bottom
closure
panel when
bottom
inlet is used.