Prime Condensate Trap With Water - Carrier 58MXA Installation, Start-Up, And Operating Instructions Manual

Deluxe 4-way multipoise fixed-capacity direct vent condensing gas furnace sizes 040o140, series 170
Table of Contents

Advertisement

_///
_1t/_
COMBUSTION
J
J
AIR
A96129
Fig. 44_Raised
SidewNl
Termination
When Wail
Penetration
is 12 in. or Less Above Snow or Grade
(Dimension
"A"
is Touching
or 2=in. Maximum
Separation}
/
J
OPEN STAND -'7
PIPE FOR /
A/C OR/
HUMIDIFIER d
DRAIN
TEE
U_
A94054
Fig. 46--Example
of Field Drain Attachment
CONDENSATE
COMBUSTION
AIR
A96130
Fig. 45--Sidewall
Termination
of More than 12 in.
(Dimension
"A"
is Touching
or 2-in.
Maximum
Separation}
UNIT
MAY
NOT OPERATE
Failure
to follow
this caution
may result
in intermittent
unit
operation
These
furnaces
are equipped
with a manual
reset limit switch
in burner box. This switch wil! open and shut offpower
to gas
valve if an overheat
condition
(flame rollout)
occurs
in burner
enclosure.
Correct
inadequate
combustion=air
supply
or ira=
proper
venting
condition
and reset
switch.
DO NOT jumper
this switch_
Befbre operating fumacQ check flanre roll=out manual reset switch
for continuity_ If necessaD', press button to reset sx_itch
WIRE
TIEq
HEAT
(3 WRAPS
MINIMUM)
36
A93036
Fig. 47--Condensate
Trap Heat Tape
Step
2--Prime
Condensate
Trap
With
Water
UNIT
MAY
NOT
OPERATE
Failure
to _bltow this caution
may result
in intem_ittent
unit
operatiom
Condensate
trap must be PRIMED
or proper
draining
may not
occur
The condensate
trap has 2 internal
chambers
which can
ONLY
be primed
by pouring
water into the inducer
drain side
of condensate
trap_
1_ Remove
upper
inducer
housing
&ain
connection
ca D (See
Fig. 48.)
Z (onnect
fiel&supplied
1i2=in_ ID
robe
to
upper
inducer
housing
&ain
connection.