Electrical Connections; 115 V Wiring - Carrier 58MXA Installation, Start-Up, And Operating Instructions Manual

Deluxe 4-way multipoise fixed-capacity direct vent condensing gas furnace sizes 040o140, series 170
Table of Contents

Advertisement

TaNe 3--Maximum
Capacity of Pipe*
NOMINAL
IRON
PIPE
SmZE
ON.)
I/2
3/4
I
1-1/4
1-1t2
iNTERNAL
DIAMETER
(IN.)
0.622
0.824
1.049
1.380
1.610
LENGTH OF PIPE (FT}
10
20
30
40
50
175
120
97
82
73
360
250
200
170
151
680
465
375
320
285
1400
950
770
660
580
2100
1460
1180
990
900
* Cubic ft of gas per hr for gas pressures of 0.5 psig (14-in
wc) or less and a
pressure drop of 0.5-in wc (based on a 060 specific gravity gas).
Ref: Table 9.2 NFGC.
FIRE
OR EXPLOSION
HAZARD
Failm'e to %llow
this wa*ning
could result
in fire, explosion,
personal
inju W, or death
-(onnect
gas pipe to 5n'nace
using a backup
wrench
to avoid
damaging
gas controls.
-Gas valve
shutoff
switch
MUST
be fhcing fbrward
or tilted
upward.
-Never
pu*ge a gas line into a combustion
chamber.
Never
test for gas leaks with
an open flame.
Use a commercially
available
soap solution
made specifically
for the detection
of
leaks to check
all connections.
-Use
proper
length
of pipe
to avoid
stress
on gas control
manifbld.
-If a /'lexible
connector
is required
or allowed
by attthori w
having
jurisdiction,
black
iron
pipe
shall
be installed
at
fimaace
gas valve
and extend
a mininmm
of 2 in
outside
furnace
casing.
Install
a sediment
trap in riser
leading
to fl/mace.
Trap can be
installed
by
connecting
a tee to
riser
leading
to
t\u'nace
so
straight-through
section
of tee is vertical
Then
connect
a capped
nipple
into lower end of tee. (apped
nipple
should extend
below
level
of gas
controls.
Place
a ground
joint
union
between
gas
control
manifold
and manual
gas shutoff
valve.
(See Fig
26.)
If local
codes allow the use of a flexible
gas appliance
connector,
always
use a new listed connector.
Do not use a connector
which
has previously
served
another
gas appliance.
FIRE
OR EXPLOSION
HAZARD
Failure
to f\fllow
the safkty warnings
exactly
could
result
in
serious
injury,
death or property
damage
Never
test for gas leaks with an open flame. Use a commer-
cially
available
soap
solution
made
specifically
for
the
detection
of leaks
to check
all connections
A fire or explo°
sion could result
causing
property
damage,
personal
ir!iury or
toss of life
An accessible
manual
shutoff valve MUST
be installed
external
to
fl/mace
casing
and within
6 ft of filmace.
A li8°in.
NPT plugged
tapping,
accessible
for test gage connection,
MLST
be installed
immediately
upstream
of gas supply
connection
to furnace
and
downstIeam
of manual
shutoff
valve
NOTE:
The gas valve
inlet pressure
tap connection
is suitable
to
use as test gauge connection
providing
test pressure
DOES
NOT
exceed
maximum
0.5 psig (14-in.
wc) stated
on gas control valve
(See Fig. 57)
GAS
SUPPLY
MANUAL
_/
II
f
A93324
Fig. 26--Typical
Gas Pipe Arrangement
Piping
should
be pressure
and
leak
tested
in accordance
with
NFG(
in the United
States or NSCNGPI(
in Canada.
local,
and
national
plumbing
and gas
codes
be_;ore the
t'urnace
has been
connected.
After all connections
have been made.
purge lines and
check
for leakage
at furnace
prior
to operating
t:urnace.
If pressure
exceeds
0.5 psig (14=in. wc), gas supply pipe must be
disconnected
from ftlrnace
and capped
be_bre pressure
test If test
pressure
is equal
to or less than
0.5 psig
(14=in. wc),
turn
off
electIic
shutoff
switch
located
on _hrnace
gas control
valve
and
accessible
manual
shutoff
valve before
test
After all connections
have been made, purge
lines and check
fbr leakage.
The
gas
supply
pressure
shall
be
within
the
maximum
and
minimum
inlet
supply pressures
marked
on the rating
plate with
the fl/rnace
burners
ON and OFF.
Step
8--Electrical
Connections
See Fig
27 for field wiring
diagram
showing
typical
field
115-v
and 24-v wiring
(hock
all fhctoo"
and field electrical
connections
for tightness
Field=supplied
wiring
shall conform
with the limitations
of 63_T
(33°(7) rise.
ELECTRICAL
SHOCK
HAZARD
Failure
to follow
this warning
could result
in serious
injury or
death
Blower
access door switch
opens
115-v power
to control.
No
component
operation
can occur
Do
not bypass
or close
switch
with panel
removed
2O
FURNACE
MAY
NOT
OPERATE/PROPERTY
DAMAGE
Failure
to %llow
this caution
may result
in fhraace
operation
stopping
and water
pipes freezing
during
cold weather.
Furnace
control
must
be grounded
for proper
operation
or
control
will
lock
out.
(ontrol
is
grounded
through
green yellow
wire
connected
to gas valve
and burner
box
SCrew,
115 V WIRING
Be_bre
proceeding
with
electrical
connections,
make
certain
that
voltage,
fi'equency,
and
phase
con'espond
to that
specified
on
furnace
rating
plate.
Also, check
to be sure that service provided