Codes And Standards - Carrier 58MXA Installation, Start-Up, And Operating Instructions Manual

Deluxe 4-way multipoise fixed-capacity direct vent condensing gas furnace sizes 040o140, series 170
Table of Contents

Advertisement

--> Never
test %r gas leaks with
an open
flame. [se
a commercially
available
soap solution
made specifically
fbr detection
of leaks to
check
all connections
as specified
in the GAS PIPING
section
of
these
instructions
--> Always
install
the Nmace
to operate
within the t_omace's intended
rise range with a duct system
which has an external
static pressure
within
the allowable
range
as specified
in the SET TEMPERA=
TURE
RISE
section
of these instructions.
--> When a fi/rnace
is installed
so that supply ducts carry air circulated
by the Nmace
to areas outside
the space
containing
the furnace,
the return
air shall also be handled
by ducts sealed
to the Nrnace
casing
and tem?inating
outside
the space
containing
the Nrnace.
--> A gas-fired
Nrnace
for installation
in a residential
garage
must be
installed
as specified
in the Hazardous
Locations
section
of these
insm_ctions,
---> The t:urnace is not to be used for tempma
W heating
of buildings
o1"
strt/ctures
under
construction
unless
the furnace
installation
and
operation
complies
with
the first (AUTION
in the LO(ATION
section
of these instructions.
This thmace
must
be installed
with a direct-vent
(combustion
air
and flue gas) system
and a factory
accessory
tei_nination
kit. In a
direct-vent
system,
all air for combustion
is taken directly
from the
outdoor
atmosphere
and flue gases are discharged
to the outside
atmosphere.
See
Nmace
and
factory
accesso_
vent-air
intake
termination
kit instructions
for proper
installation.
These fimaaces
are shipped
with the following
materials
to assist in
proper
furnace
installation.
These materials
are shipped
in the main
blower
compartment.
Installer Packet includes:
Installation, Startup, and Operating instructions
Service and Maintenance
instructions
User's Information Manual
Warranty Certificate
Loose Parts Bag includes:
Quantity
Pressure tube extension
1
Collector Box or condensate
trap extension tube
1
inducer housing drain tube
1
l/2qn CPVC street elbow
2
Drain tube coupling
1
Drain tube coupling grommet
1
Vent and combustion-air
pipe support
2
Condensate
trap hole filler plug
3
Vent and combustion-air
intake hole filler plug
2
Combustion-air
pipe perforated disk assembly
1
Vent Pipe Extension
1"
ONLY supplied with some furnaces.
For accessory
installation
details,
refer
to accessory
installation
instl_._ctions.
_NTRODUCTmON
The model
58MXA
4=way multipoise,
Gas=Fired,
Category
IV,
direct-vent
condensing
fitrnace
is available
in model
sizes ranging
in input capacities
of 40,000
to 138,000
Bmh
CODES
AND
STANDARDS
FMIow all nationM
and locM codes and standards
in addition
to
these
instructions°
The installation
must comply
with regulations
of the serving
gas supplier,
local building,
heating,
plurnhing,
and
other
codes.
In absence
of local
codes,
the
installation
must
comply
with
die national
codes
listed
below
and all authorities
having
jurisdiction.
In the United States and Canada,
%llow
all codes and standards
%r
the fbllowing:
Step
l--Safety
US: National
Fuel
Gas (7ode (NFGC)
NFPA
54-2002/ANSI
Z223.1-2002
and the Installation
Standards,
Warm
Air Heating
and Air Conditioning
Systems
ANSI
NFPA
90B
(ANADA:
National
Standard
of Canada,
Natural
Gas
and
Propane
Installation
(ode
(NSCNGPIC)
CANiCGA
-B149,1
=and2
M=00
Step
2--General
Installation
US: NFGC and the NFPA 90B. For copies,
contact
the National
Fire Protection
Association
Inc,
Battewmarch
Park,
Quincy,
MA 02269;
or for only the NFG(
contact
the American
Gas
Association,
400 N. (apitol,
N.W.,
Washington
DC 20001
--> *
A manufhctured
(Mobile)
home installation
must confbrm
with
the Manzt_bctured
_12)me Construction
and
5"qfi._ 0 ' Standard,
Tide
24
(_FR,
Part
3280,
or when
this
standard
is not
applicable,
the Standard
fbr :l,Ian@mtzcred
Home
in.stgd/ation
(._Iclmt/actHred
D))me
Sites,
('omm_¢nitie.s,
and
Set-L_.s),
A_ifZ,.VCS'
A225. I, an_or
(it_\-_ (WA-Z240,
MN Serie,s Mofile
(ANADA:
NSCNGPI(L
For a copy_ contact
Standard
Sales,
CSA
International,
178 Rexdale
Boulevard,
Etobicoke
(Tot=
onto),
Ontario,
MPW
1R3, Canada.
Step
a--Combustion
and Ventilation
Air
US:
Section
53
of the
NFG(,
Air
for
(ombnstion
and
Ventilation
CANADA:
Part 7 of the NSCNGPIC,
Venting
Systems
and Air
Supply
for Appliances
Step
4--Duct
Systems
US and CANADA:
Air
(onditioning
(ontractors
Association
(ACCA)
Manual
D, Sheet
Metal
and Ai* Conditioning
Con=
tractors
National
Association
(SMACNA),
or American
Soci-
ety of Heating,
Refrigeration,
and Air Conditioning
Engineers
(ASHRAE)
200I
Fundamentals
Handbook
Chapter
34
Step
g--Acoustical
Lining
and Fibrous
Glass
Duct
Ers and CANADA:
cmTent edition
of' SMACNA,
NFPA 90B as
tested
by EL Standard
18! for Class I Rigid
Air Ducts
Step
g--Gas
Piping
and Gas Pipe Pressure
Testing
US: NFGC
chapters
2, 3, 4_ and 9 and national
plumbing
codes
--> In the state of Massachusetts:
*
This product
must
be installed
by a licensed
plun_her
or gas
fitter
*
When
flexible
connectors
are used,
the maximum
length
shall
not exceed
36 inches
*
When lever type gas shutoff?4 are used they shall not exceed
36
inches
*
CANADA:
NSCNGPI(
Parts
3, 4, 5, A, B, E, and H.
Step
7--Electrical
Connections
*
US: National
Electrical
Code (NEC)
ANSIiNFPA
70=2002
*
(ANADA:
Canadian
Electrical
Code CSA
(22
1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents