Rs-232/Usb Com Parameters; Intercharacter Delay - Datalogic Touch 90 pro Product Reference Manual

General purpose corded handheld contact imager bar code reader
Hide thumbs Also See for Touch 90 pro:
Table of Contents

Advertisement

RS-232 Parameters

RS-232/USB COM Parameters

Intercharacter Delay

This parameter specifies the intercharacter delay between the end of one character and the
beginning of the next. The delay can be set within a range of zero (0) to 990 milliseconds in
10ms increments. A setting of zero specifies no delay.
To set the delay:
1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 10 (setting is in 10ms increments). Pad the result with lead-
3. Scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Programming
4. Go to
5. Scan the appropriate two digits from the keypad in
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit.
This completes the procedure. See the following table for examples of how to set this feature.
Table 4. Intercharacter Delay Setting Examples
STEP
ACTION
1
Desired Setting
Divide by 10 (pad with leading
2
zeroes to yield two-digits)
3
4
Scan Two Characters From
5
Appendix D, Keypad
6
Product Reference Guide
ing zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
Mode.
and scan the bar code: SELECT INTERCHARACTER DELAY SET-
page 25
TING.
duration which was determined in the steps above. You will hear a two-beep indication
after the last character.
If you make a mistake before the last character, scan the CANCEL bar code to
abort and not save the entry string. You can then start again at the beginning.
NOTE
50ms
05
Scan ENTER/EXIT PROGRAMMING MODE
Scan SELECT INTERCHARACTER DELAY SETTING
'0' and '5'
Scan ENTER/EXIT PROGRAMMING MODE
Appendix D, Keypad
EXAMPLES
150ms
600ms
15
60
'5' and '0'
'6' and '0'
References
, that represent the
850ms
85
'8' and '5'
253

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents