Bc412 Check Character Calculation; Bc412 Minimum Reads - Datalogic Touch 90 pro Product Reference Manual

General purpose corded handheld contact imager bar code reader
Hide thumbs Also See for Touch 90 pro:
Table of Contents

Advertisement

Enter/Exit Programming Mode

BC412 Check Character Calculation

Enable this option to enable/disable calculation and verification of an optional BC412 check
character. When disabled, any check character in the label is treated as a data character.
DEFAULT
$CBCCC01
BC412 Check Character Calculation = Calculate Check
Character

BC412 Minimum Reads

This feature specifies the minimum number of consecutive times a BC412 label must be
decoded before it is accepted as good read.
$CBCMR02
BC412 Minimum Reads = 2
$CBCMR04
BC412 Minimum Reads = 4
238
$CBCCC00
BC412 Check Character Calculation = Don't Calculate
$CBCMR01
BC412 Minimum Reads = 1
DEFAULT
$CBCMR03
BC412 Minimum Reads = 3
BC412
Touch TD1100