Checking The Wastegate Flap - Rotax 914 series Maintenance Manual

914 series;
Hide thumbs Also See for 914 series:
Table of Contents

Advertisement

8) Checking the wastegate flap

See
General note
The following checks must be carried out:
Checks
Step
1
2
3
4
Effectivity: 914 Series
Edition 2 / Rev. 0
BRP-Powertrain
MAINTENANCE MANUAL
Fig.
11.
Damage to the bowden cable is not permissible. If only
NOTICE
WARNUNG
1 flexible wire of the bowden cable is abraded, the ca-
ble must be replaced. See 78-00-00 of the Heavy
Maintenance Manual.
Check the bowden cable of the wastegate actuation (1) for mechanical dam-
age or wear.
Check the bowden cable suspension and spring.
Check the adjustment of the wastegate flap.
NOTES:
When the engine has been shut down, the servo motor al-
ways runs to closed position.
This also applies when the TCU is switched on. The servo
motor moves approx. 1/2 revolution and then remains in
closed position.
In this position, the wastegate flap must be completely closed. If necessary,
readjust using the adjusting screw (2). See 78-00-00 of the Heavy Mainte-
nance Manual.
Check the wastegate lever (3) for free movement.
NOTES:
If it does not move freely, lubricate the axle (lubrication hole)
of the wastegate with LOCTITE Anti-Seize 8151, ROTAX
part no. 297434.
Procedure
12-20-00
page 23
January 01/2010

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mml-914

Table of Contents