1) Scheduled maintenance checks
This section lists the periodic inspections which must be carried out after
Definition
a specified period of operation.
Periodic inspections are those which must be performed at 50, 100, 200,
Intervals
600 hr. intervals in accordance with chap. 05-20-00. section:
This means for example that every 100 hr. of operation a 100 hr. check
and all 200 hr. additional checks as per maintenance check list must be
carried out.
100 hr
200 hr
600 hr
- In order to demonstrate continued airworthiness, an engine must be
100 hr.
check
- For the intervals between maintenance work, a tolerance of ±10 hr. is
- If maintenance is performed before the prescribed interval, the next
NOTES:
Special hr. check
- In order to demonstrate continued airworthiness, an engine must be
25-hr.
check
- The checks performed at the 25 hr. inspection are the same as for the
Effectivity: 914 Series
Edition 2 / Rev. 0
BRP-Powertrain
MAINTENANCE MANUAL
25 hr 100 hr 200 hr 300 hr 400 hr 500 hr 600 hr 700 hr to
X
X
X
X
inspected after every 100 hours of operation.
permissible, but these tolerances must not be exceeded. This means
that if a 100 hr. check is actually carried out at 110 hr., the next check
will be due at 200 hr. ±10 hr. and not at 210 hr. ±10 hr.
maintenance check is to be done at the same interval (e.g. if first
100 hr. check is done after 87 hours of operation, the next 100 hr.
check must be carried out after 187 hours of operation).
This maintenance schedule contains a column for a 50 hr.
check. This check is recommended by the manufacturer
but not essential, with the exception of oil change when
operating with leaded AVGAS.
inspected after the first 25 hours of operation.
100 hr. inspection. This applies both to newly delivered engines and to
overhauled engines.
Intervals - hours
X
X
X
X
5.1).
2000
hr
X
X
X
X
X
05-20-00
page 3