Rotax 914 series Maintenance Manual page 63

914 series;
Hide thumbs Also See for 914 series:
Table of Contents

Advertisement

Points of Inspection
On configurations with auxiliary generator, check the
attachment and the V-belt tension.
Check the electric fuel pumps.
Replace the main fuel pump.
Observe the safety instructions!
Start the engine and run to operating temperature.
Limits see Operators Manual 914 series.
Ignition check at _____ rpm engine speed.
Speed drop without ignition circuit:
A (Off)___________rpm
B (Off)___________rpm
A/B (difference)________rpm
After engine test run, re-tighten the oil filter by hand
(only at cold engine).
Checks for leaks.
All Service Instructions and Service Bulletins are
complied with.
Returning engine to service
On the engine identified as per point 5, on the _____________________ the________hr.
Check at______hr. (TSN___, TSO___) was carried out according to recommendations of the engine manufac-
turer and was recorded in the Engine Log book.
Location, Date_______________________
Inspector___________________________
Aircraft mechanic_____________________
Certificate No.______________________
Effectivity: 914 Series
Edition 2 / Rev. 0
BRP-Powertrain
MAINTENANCE MANUAL
Interval
Operating hours
as
indicated
17.) Checking the V-belt tension
18.) Electric fuel pumps
every 1000 hr.
every 1000 hr.
19.) Engine test run
General note
Chapter
Reference
100 hr.
X
12-20-00
sec. 6)
MM II
(Heavy)
73-00-00
sec. 3.4.6)
IM
sec. 14.4)
X
12-20-00
sec. 8)
X
05-20-00
January 01/2010
Signature