High altitude operation

At high altitude, the standard carburetor air-fuel mixture will be excessively rich.
Performance will decrease, and fuel consumption will increase.
High altitude performance can be improved by installing a smaller diameter main
fuel jet in the carburetor and readjusting the pilot screws. lf you always operate the
generator at altitudes higher than 1,500 m(5,000 feet) above sea level, have your
authorized KIPOR dealer perform these carburetor modifications.
Even with suitable carburetor jetting, engine horsepower will decrease approximately
3.5% for each 305m (1,000 feet) increase in altitude. The affect of altitude on the
horsepower will be greater than this if no carburetor modification is made.
CAUTION
Operation of the generator at an altitude lower than
the carburetor is jetted for may result in reduced
performance,overheating,and serious engine damage
caused by an excessively lean air/fuel mixture.
7.STOPPING THE ENGINE
To stop the engine in an emergency, turn the engine switch to the OFF position.
IN NORMAL USE:
1.Switch off the connected equipment and pull the inserted plug.
2.Turn the engine switch to the OFF position.