Low oil alarm system

The low oil alarm system is designed to prevent engine damage caused by an insufficient amount
of oil in the crankcase. Before the oil level in the crankcase falls below a safe limit, the low oil
alarm system will automatically shut down the engine (the engine switch will remain in the ON
position).
If the low oil alarm system shuts down the engine, the low oil alarm indicator light (red) will come
on when you operate the starter and the engine will not run. If this occurs add engine oil.

Air Conditioning Operation

When running in parallel (see section 8) the combination of an IG1000P and either an IG2000P or
IG2600P model can start and run most 13,500 BTU Air conditioners. An IG2000P and an
IG2600P or two IG2600P models will start and run most 15000 BTU units. For best results, the
SMART throttle switches should be in the off position. Bring the generators to normal operating
temperatures before applying the air conditioning load. Always allow a 2 minute wait period when
manually cycling an air conditioner off and on. A longer wait period may be required under
unusually hot weather conditions. Additionally, all other loads should be turned off until the air
conditioner has started and is performing normally. It is also important to follow the air conditioner
manufacturer's instructions for starting and restarting for proper operation. Some air conditioner
manufacturers offer a start capacitor or rapid start kit as an extra cost option. The lack of a start
capacitor can cause the air conditioner to draw too high a starting current and overload the
generators. Contact your air conditioner dealer if you consistently have problems starting your air
conditioner with the generators in parallel.
LOW OIL ALARM
INDICATOR LIGHT (red)
23