Mesh Prerequisites; Pxu (Proximunify) Prerequisites; System Requirements - Proxim ORiNOCO AP-4000M User Manual

Hide thumbs Also See for ORiNOCO AP-4000M:
Table of Contents

Advertisement

Installation and Initialization

System Requirements

Mesh Prerequisites

Before setting up a Mesh network, gather the following information:
Parameter
Mesh Mode
Mesh Interface Number
Mesh SSID
Mesh Security Mode
Mesh AP Shared Secret

PXU (ProximUnify) Prerequisites

Before setting up a PXU Profile, gather the following information:
Parameter
Module Parameters
PXU IP Address
Domain Name
Shared Secret/ Confirm Shared
Secret
Response Time
Retransmission
Module Status
System Requirements
To begin using an AP, you must have the following minimum requirements:
A 10Base-T Ethernet or 100Base-TX Fast Ethernet switch or hub or cross-over Ethernet cable
At least one of the following IEEE 802.11-compliant devices:
An 802.11a, 4.9 GHz, 802.11b, or 802.11b/g client device
A computer that is connected to the same IP network as the AP and has one of the following Web browsers installed:
Microsoft® Internet Explorer 6 with Service Pack 1 or later and patch Q323308
Netscape® 7.1 or later
The mode in which the AP will be used. If the AP will be connected directly to the wired
backbone, it should be configured for Mesh Portal mode; if it will connect to the Portal
and backbone wirelessly, it should be configured for Mesh AP mode. If the AP will not
be used in a Mesh network, Mesh Mode can be disabled.
The interface on which the Mesh functionality will be enabled. For Wireless A, the
interface number is 3; for Wireless B, the interface number is 4.
The name of the Mesh network. The Mesh SSID should be between 1 and 16
characters.
Mesh links may be secured through AES encryption. You may also choose to use
Mesh functionality without security enabled (not recommended).
The password shared between Mesh Access Points when AES is enabled (AES is
enabled by default). This password should be between 6 and 32 characters. The
default password is public.
Configure the Primary and Secondary Modules parameters
This field is for IP address of the PXU unit. The default is 0.0.0.0.
The field where the domain name will be written.
The password is shared by the PXU module and the AP. The same password must
also be configured on the PXU module. The default password is "public."
This is the maximum time, in seconds, that the AP should wait for the PXU module to
respond to a request. The range is 1-10 seconds; the default is 3 seconds.
The maximum number of times an authentication request may be transmitted. The
range is 0 to 4, the default is 3.
The status of the PXU Profile
AP-4000/4000M/4900M User Guide
Description
Description
23

Advertisement

Table of Contents