Figure 4-9
Master switch
Water Trap Bleed
Usually located on the right-hand side truck frame, near mid-section, the water trap bleed (see Figure
4-10) must be drained at the end of every working day. Just slacken off both water trap bleed screws
under the bowls and catch the water and oil that flow out with a rag. The water trap helps keep
moisture out of the air system.
Figure 4-10
Water trap bleed
Emergency Actions
Hydraulic Oil Spill
In case of hydraulic spill, do the following:
Press the emergency red button (see Figure 3-25).
1.
Turn off the pump switch (see Figure 3-16).
2.
Pump switch should be blue-lighted.
Turn off the truck engine.
3.
Screws
Operating the W
Bowls
P
™ 91