Minimum Framing Dimensions - Rear Vent Configuration
HINT: place the fireplace so the center
line is at least 5" from both vertical framing
members at the rear (this allows the vent
to pass through the framing without
modfications)
Route the
electrical line to
a position to the
left rear of the
fireplace.
Minimum enclosure height = 38-1/2"
© Travis Industries
Installation
(for qualified installers only)
38-1/2"
41-1/4"
WARNING: A cut-out for the gas line
may be required on the framing. See
the dimensions under"Gas Line
Connection" for details.
Included Firestop (required)
Part # 93006094
38"
25-3/4"
20"
4050714
Vent Clearances (8" dia. Vent):
1" to the sides, 1" below, and 3" above
the vent to combustibles.
Center of Rear Vent
30-3/4"
The on/off switch/thermostat wire (if
used) should be routed to a location
near the right front of the fireplace.