Thick Facing Installation With Fpx Arched Faces - Travis Industries 864TRV Installation Manual

Hide thumbs Also See for 864TRV:
Table of Contents

Advertisement

Thick Facing with Fireplace Xtrordinair (FPX) Arched Faces
The following illustration shows facing considerations for those fireplaces utilizing FPX arched faces.
The facing must be non-combustible and over 1" in depth.
The Fireplace Xtrordinair 864
Masonry Template is
recommended for masonry
installation (sku 98500688). The
template helps locate and
support the masonry as it being
installed.
Before installing masonry, install
the FPX Face Upgrade Kit
(98500686). This covers the
upper corners.
TOP VIEW
Framing
Fireplace
Face
Masonry
© Travis Industries
Installation
Nailing Bracket
Drywall
(for qualified installers only)
Masonry Line
Floor-Mounted Fireplaces or Raised Hearths:
Build the hearth 1" (max.) above the base of the
fireplace. The fireplace may be raised to
accommodate thicker hearth materials.
Raised Fireplaces:
Masonry is installed 1" (maximum)
above the base of the fireplace.
FRONT VIEW
41"
4050714
45-1/2" Radius
37
5"
35-3/4"
1"
100-01173_001