Top Vent Configuration With Horizontal Termination - Travis Industries 864TRV Installation Manual

Hide thumbs Also See for 864TRV:
Table of Contents

Advertisement

28

Top Vent Configuration with Horizontal Termination

The termination must fall within the shaded area shown in the chart. Use the indicated restrictor
and diffuser positions.
Up to four elbows (45° or 90°) may be used.
May use 8" or 6-5/8" diameter vent (see page for 20 details).
Only one horizontal elbow may be used.
21' (max)
20 feet
15 feet
10 feet
5 feet
0 feet
This is considered a horizontal
elbow (it does not matter
whether it turns right or left).
It may be a 90° or 45° elbow.
Travis Industries
Installation
(for qualified installers only)
H2
H1
Exhaust Restrictor # 4
Intake Restrictor # 2
Diffuser Position # 2
Exhaust Restrictor # 1 (stock)
Intake Restrictor # 1 (stock)
Diffuser Position # 1 (stock)
Horizontal length is calculated by adding
both lengths of horizontal run
(Horizontal Length = H1 + H2).
This is considered a
vertical elbow
4050714
21' (max)
20 feet
15 feet
10 feet
5 feet
0 feet
100-01173_001

Advertisement

Table of Contents
loading

Table of Contents