WARNING:
If the information in these instructions is not followed exactly, a fire or explosion may result
causing property damage, personal injury or loss of life.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency or the gas supplier.
A barrier designed to reduce the risk of burns from
the hot viewing glass is provided with this appliance
and shall be installed for the protection of children
and other at-risk individuals.
This appliance may be installed in an aftermarket, permanently located, manufactured home
(USA only) or mobile home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. A conversion
kit is supplied with the appliance.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Travis Industries, Inc.
 Copyright 2014, T.I.
864 TRV Deluxe
(with screen)
Installation Manual
HOT GLASS WILL CAUSE
BURNS
DO NOT TOUCH GLASS
UNTIL COOLED
NEVER ALLOW CHILDREN
TO TOUCH GLASS
12521 Harbour Reach Dr., Mukilteo, WA 98275
$10.00
 Built-In Direct Vent
 Natural Gas or Propane
 Residential or Mobile
4140611
Tested and Listed by
Report # B0516PRT-001
ANSI Z21.88-2014
CSA 2.33-2014
Fireplace
Home
www.travisproducts.com
100-01387

Advertisement

Table of Contents
loading

Summary of Contents for Travis Industries 864 TRV Deluxe

  • Page 1 864 TRV Deluxe (with screen) Installation Manual WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
  • Page 2: Overview

    A copy is shown to the right. Massachusetts Approval This manual has been submitted to the Massachusetts Board of State Examiners of Plumbers and Gas Fitters National Fireplace Institute © Travis Industries 4140611 100-01387...
  • Page 3: Table Of Contents

    Termination (no vertical rise) ......29   Grill Installation ........... 62   Rear Vent Configuration with Horizontal Wiring Diagram ............63   Termination (with vertical rise) ......30   Index ..............64 Rear Vent Configuration with Vertical   Termination ............31 Travis Industries 4140611 100-01387...
  • Page 4: Safety Warnings

    Do not operate if any portion of the heater was submerged in water or if any corrosion occurs. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. Travis Industries 4140611 100-01387...
  • Page 5  Travis Industries, Inc. grants no warranty, implied or stated, for the installation or maintenance of your heater, and assumes no responsibility of any consequential damage(s).
  • Page 6: Installation Options

    38-1/4" 184mm Rear Vent Configuration 972mm 8" (203mm) Ø Vent 38-1/4" 972mm 36-3/4" 933mm 35-1/4" 895mm 1" 25mm 37" 30-3/4" 940mm 781mm 28-5/8"* 728mm* 41" 20-3/4"* 1041mm 528mm* * See "Clearances" and "Framing Dimensions" for details. Travis Industries 4140611 100-01387...
  • Page 7: Packing List

    Install the vent, gas line and electrical hook-up.  Install the drywall.  Install the hearth (if applicable).  Install the facing (if applicable).  Install the mantel (if applicable).  Finalize the installation (see page 46) and install the grill or face. Travis Industries 4140611 100-01387...
  • Page 8: Massachusetts Requirements

    A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. See Gas Connection section for additional Commonwealth of Massachusetts requirements. Travis Industries 4140611 100-01387...
  • Page 9: Top Vent Or Rear Vent Configuration

    This part may be discarded. Remove the 4 screws securing the intake cover plate. Remove it and place it aside. Remove and discard all of the insulation found near the flue assembly (make sure to remove every piece). Travis Industries 4140611 100-01387...
  • Page 10: Converting The Fireplace To Top Vent (Continued)

    DO NOT OVER- TIGHTEN THE SCREWS. Attach the intake cover plate with the screws removed earlier. Attach the cover plate with the screws removed earlier. NOTE: flatten the four legs before insaling the cover plate. Travis Industries 4140611 100-01387...
  • Page 11: Fireplace Placement Requirements

    The fireplace (and hearth, if desired) may be placed on a platform designed to support the fireplace (205 Lbs. 93 Kg) and vent.  The base of the fireplace must be a minimum 70” (1778mm) below the room ceiling. Travis Industries 4140611 100-01387...
  • Page 12: Minimum Framing Dimensions - Rear Vent Configuration

    Center of Rear Vent Route the 30-3/4" electrical line to 781mm a position to the 38" left rear of the 965mm fireplace. 25-3/4" 654mm 38-1/2" 978mm 41-1/4" 20-3/4" 1048mm 528mm Minimum enclosure height = 38-1/2" (978mm) Travis Industries 4140611 100-01387...
  • Page 13: Minimum Framing Dimensions - Top Vent Configuration

    (for qualified installers only) Minimum Framing Dimensions - Top Vent Configuration Route the electrical line to a position to the left rear of the fireplace. 38-1/2" 978mm 41-1/4" 20-3/4" (528mm) 1048mm Minimum enclosure height = 38-1/2" (978mm) Travis Industries 4140611 100-01387...
  • Page 14: Televisions Placed Above The Fireplace

    The homeowner must understand that Travis Industries does not take responsibility for any negative impact to televisions placed near this fireplace. Min. 1" (26mm) Air Gap Behind TV Television (TV) Min.
  • Page 15: Using A Buildout Above Fireplace And Television

    The homeowner must understand that Travis Industries does not take responsibility for any negative impact to televisions placed near this fireplace. Min. 1" (26mm) Air Gap Behind TV Min.
  • Page 16: Using A Buildout Below A Television

    The homeowner must understand that Travis Industries does not take responsibility for any negative impact to televisions placed near this fireplace. Min. 1" (26mm) Air Gap Behind TV...
  • Page 17: Nailing Brackets

    (approx. 54-7/8” – 1394mm). See the illustration below. Use shims to insure the fireplace is square. 54-7/8'' (1394mm) Additional nailing brackets are provided along the base of the fireplace. Use these brackets if not using the front brackets. 1/2''(13mm) 1/2" (13mm) 5/8''(16mm) 5/8" (16mm) Travis Industries 4140611 100-01387...
  • Page 18: Corner Installations - Rear Vent Configuration

    Approximate (varies due to vent installation) NOTE: Most installations use: 6" (152mm) Section for 2 X 6 Walls (51mm X 152mm) 4" (102mm) Section for 2x4 Walls (51mm X 102mm) (Travis # 98900166) 50-1/2" Min. 1283mm Travis Industries 4140611 100-01387...
  • Page 19: Corner Installations - Top Vent Configuration

    (for qualified installers only) Corner Installations - Top Vent Configuration A typical 45° installation uses the framing dimensions shown in the illustration below (NOTE: all clearances still apply). Minimum 1/2" (13mm) Clearance 15-1/2" 394mm 50-1/2" Min. 1283mm Travis Industries 4140611 100-01387...
  • Page 20: Outdoor Fireplace Installations

    Installation (for qualified installers only) Outdoor Fireplace Installations Travis Industries Inc. gas-fired fireplaces are suitable for installation into outdoor areas protected from direct water impingement. In addition to maintaining listed mantel and combustibles clearances, a rain protection overhang factor of 1/2 shall be constructed to the front and to each side of installed appliances (see the illustration to the right).
  • Page 21: Gas Line Requirements

    The supply regulator (the regulator that attaches directly to the residence inlet or to the propane tank) should supply gas at the suggested input pressure listed above. Contact the local gas supplier if the regulator is at an improper pressure. Travis Industries 4140611 100-01387...
  • Page 22: Gas Line Location

    4. Attach the shutoff valve plate to the left side of the fireplace. Route the gas line to the left side and re-attach the gas line to the shutoff valve. Make sure to leak test the entire gas line. Travis Industries 4140611...
  • Page 23: Electrical Connection (Required)

    The electrical line must be a min. 14 gauge, and supply 120 Volts at 60 Hz (2 Amps). Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Travis Industries 4140611 100-01387...
  • Page 24: Vent Requirements

     Failure to adjust the air shutter properly may lead to improper combustion which can create a safety hazard. Consult your dealer or installer if you suspect an improperly adjusted air shutter. Travis Industries 4140611 100-01387...
  • Page 25: Approved Vent

    If it does not, apply high temperature sealant to the joints of the affected sections.  Horizontal sections require a 1/4" (6mm) rise every 12" (305mm) of travel  Horizontal sections require non-combustible support every three feet (e.g.: plumbing tape) Travis Industries 4140611 100-01387...
  • Page 26: Approved Vent Configurations

    The rear screw location indicates restrictor position. In this example, the restrictor is set in position # 3. Tighten the screws to secure the restrictor. (closed) #6 (open - stock position) # 1 Back of Firebox Travis Industries 4140611 100-01387...
  • Page 27: Intake Restrictor Adjustment

    Loosen the two screws holding the intake restrictor in place.. Position # 1 (open) Slide the restrictor down to the second position and tighten the screws. Position # 3 (not used) Position # 2 (open) Travis Industries 4140611 100-01387...
  • Page 28: Diffuser Plate Adjustment

    Bend the round portion of the diffuser so it is flat (position # 2). After (Position # 2) Secure the flattened diffuser plate with the screws removed earlier. Replace the exhaust restrictor (see “Exhaust Restrictor Adjustment” for restrictor settings). Travis Industries 4140611 100-01387...
  • Page 29: Rear Vent Configuration With Horizontal Termination (No Vertical Rise)

    Vent with 1 45° Elbow 3 feet (0.915m) • Exhaust Restrictor # 1 (stock) • Intake Restrictor # 1 (stock) • Diffuser Position # 1 (stock) 0 feet • Min. 4" (102mm) Horizontal Section • Max. 24" (610mm) Horizontal Section(s) Travis Industries 4140611 100-01387...
  • Page 30: Rear Vent Configuration With Horizontal Termination (With Vertical Rise)

    (it does not matter both lengths of horizontal run whether it turns right or left). (Horizontal Length = H1 + H2). It may be a 90° or 45° elbow. This is considered a vertical elbow Travis Industries 4140611 100-01387...
  • Page 31: Rear Vent Configuration With Vertical Termination

    (it does not matter both lengths of horizontal run whether it turns right or left). (Horizontal Length = H1 + H2). It may be a 90° or 45° elbow. This is considered a vertical elbow Travis Industries 4140611 100-01387...
  • Page 32: Top Vent Configuration With Horizontal Termination

    (it does not matter both lengths of horizontal run whether it turns right or left). (Horizontal Length = H1 + H2). It may be a 90° or 45° elbow. This is considered a vertical elbow Travis Industries 4140611 100-01387...
  • Page 33: Top Vent Configuration With Vertical Termination

    (it does not matter both lengths of horizontal run whether it turns right or left). (Horizontal Length = H1 + H2). It may be a 90° or 45° elbow. This is considered a vertical elbow Travis Industries 4140611 100-01387...
  • Page 34: Termination Requirements

    NOTE: Measure clearances to the nearest edge of the exhaust hood. • Use the vinyl siding standoff when installing on an exterior with vinyl siding. • Vent termination must not be located where it will become plugged by snow or other material Travis Industries 4140611 100-01387...
  • Page 35: Hearth Requirements

    Raised A hearth is not required Fireplaces when the fireplace is raised above the flooring surface. Fireplace Stand Travis Industries 4140611 100-01387...
  • Page 36: Facing Requirements

    If the fireplace is raised, drywall up to the bottom edge as well. Do not install drywall (or any other combustible) in front of the fireplace. TOP VIEW Framing Nailing Bracket Fireplace Drywall Travis Industries 4140611 100-01387...
  • Page 37: Facing Overview

    41” (1041mm) May fit over top of tile facing Winthrop Bungalow 34” (864mm) 36-7/8” (937mm) Optional facing will butte to edge of faceplate (tile line) Shadowbox 38.0625” (967mm) 50” (1270mm) Face extends 1” below base of fireplace Travis Industries 4140611 100-01387...
  • Page 38: Thin Facing Installation (Tile, Marble, Or Other Non-Combustible Under 1" (25Mm) Thick)

    FPX arched faces require the FPX Face 870mm Upgrade Kit (sku 98500686) and a triangular piece of facing in these upper corners. See the instructions included with the face for further details. 7-7/8" (200mm) 1" (25mm) 2-7/8" 37" 2" (51mm) (73mm) 940mm Travis Industries 4140611 100-01387...
  • Page 39: Thin Facing Installation (Tile, Marble, Under 1" (25Mm) Thick) - Side View

    Tile or other facing under 1'' (25mm) thick. Face SIDE OF FIREPLACE Hearth: note how it extends under the face - max. 1'' (25mm) thick. The fireplace may be raised to accommodate thicker hearth materials. Max. 1'' (25mm) Floor Travis Industries 4140611 100-01387...
  • Page 40: Thick Facing Installation (Stone, Brick, Or Other Non-Combustible Over 1" (25Mm) Thick)

    (or cement board, etc.) Masonry 1" NOTE: The nailing brackets are not used for this type of installation - secure the fireplace to the floor with 41" the brackets along the base of the fireplace. 1041mm Travis Industries 4140611 100-01387...
  • Page 41: Thick Facing With Fireplace Xtrordinair (Fpx) Arched Faces

    Masonry is installed 1" (25mm) maximum (98500686). This covers the above the base of the fireplace. upper corners. FRONT VIEW 5" 127mm TOP VIEW Framing 35-3/4" 45-1/2" (1156mm) Radius 908mm Nailing Bracket Fireplace Drywall Face Masonry 1" 41" 1041mm Travis Industries 4140611 100-01387...
  • Page 42: Thick Facing Installation - Side View

    Drywall Raised Fireplace (with no Hearth) Masonry or other non-combustible over 1'' (25mm) thick. SIDE OF FIREPLACE Face (Behind Masonry) The masonry extends 1'' (25mm) above the base of the fireplace. 1'' (25mm) Fireplace Support Floor Travis Industries 4140611 100-01387...
  • Page 43: Mantel Requirements

     A non-combustible SIDE OF FIREPLACE Non-Combustible Mantel header must be used (metal stud). Non-Combustible Facing Travis Industries 4140611 100-01387...
  • Page 44: Installation Example - Build-Out (Dog-House) With Hor. Termination

    1/2'' (13mm) Clearance to Insulation require an insulated enclosure. sides and back of fireplace. NOTE: If required to use drywall inside the firebox enclosure, make sure to alter the framing accordingly. Vapor Barrier Drywall Optional Tile Travis Industries 4140611 100-01387...
  • Page 45: Installation Example - Build-In With Horizontal Termination

    Top View NOTE: 1/2'' (13mm) Clearance to Insulation sides and back of fireplace. NOTE: If required to use drywall inside the firebox enclosure, make sure to alter the framing accordingly. Drywall Optional Tile Travis Industries 4140611 100-01387...
  • Page 46: Steps For Finalizing The Installation

    (AC) power goes out and are required for operation. Install three AAA batteries into the remote (see illustration below). Synchronize the transmitter to the IFC. Install the logs (see page 51). Replace the glass. Start the heater. Leak test all gas joints. Travis Industries 4140611 100-01387...
  • Page 47: Air Shutter Adjustment

    (this is used primarily with brick faces). Acid wash (muriatic acid) is used to remove excess mortar. If not properly neutralized with an ammonia solution, the plated face may develop a permanent tarnish when the acid evaporates over time. Contact your dealer if uncertain your facing has been properly neutralized. Travis Industries 4140611 100-01387...
  • Page 48: Barrier Removal

    HINT FOR REPLACING THE BARRIER: Hold the barrier at an angle and insert the bottom slots first. Then pivot the barrier forward to engage the top hooks. Travis Industries 4140611 100-01387...
  • Page 49: Glass Frame Removal And Installation

    Lift the glass frame slightly and attach the lower latches. NOTE: Make sure the glass frame is all the way in place - it should be flush with the front of the fireplace when installed. Travis Industries 4140611 100-01387...
  • Page 50: Glass Frame Removal And Installation (Continued)

    Top of Firebox Glass Frame Anchor Note how the washer on the latch fits behind the flange on the glass frame anchor. Once fully inserted, turn the latch until it is upright. Travis Industries 4140611 100-01387...
  • Page 51: Log Set Installation

    When installed, the ten (10) logs should appear as shown below. The directions on the following pages detail installation of this log set. Back Log Center Log Right Twig Left Log Center Left Twig Left Twig Center Twig Front Left Log Right Log Front Ember Chunk Travis Industries 4140611 100-01387...
  • Page 52: Back Log

    The log straddles the burner and does not cover any burner holes. Right Log The right log has a channel on the bottom that fits over the grate. Place the log in place and slide it to the rear. Travis Industries 4140611 100-01387...
  • Page 53: Front Left Log

    Left Log The left log has a channel on the bottom. Place this channel over the grate. When in place, make sure the log is positioned so it does not block any burner holes. Travis Industries 4140611 100-01387...
  • Page 54: Center Twig

    (make sure it is not over any burner holes). Front Ember Chunk The front ember chunk has a groove on the bottom that fits over the grate. Place it as shown below. Travis Industries 4140611 100-01387...
  • Page 55: Left Twig

    Make sure the twig is positioned so it does not cover any burner holes. Travis Industries 4140611...
  • Page 56: Center Log

    Make sure the fork on the front of the log fits over the grate as shown below. Right Twig The right twig has a hole on the bottom that fits over the pin on the right log. Position the twig so it rests on the back log as shown below. Travis Industries 4140611 100-01387...
  • Page 57: Ember Installation

    Use a stiff brush to apply a thin layer of rockwool fibers onto the burner. Do not use the entire bag of rockwool. Use only a small amount and save the remainder. Over-use of rockwool will diminish the glow and may cause sooting or other adverse conditions. Travis Industries 4140611 100-01387...
  • Page 58: Lp Conversion Instructions

    Lift the front burner, slide it to the right, and lift it from the firebox. When replacing the burner make sure it is properly located. The rear burner air shutter support will need to be removed to access the orifice. Remove the support and place it aside. Travis Industries 4140611 100-01387...
  • Page 59 Orifice Front Burner Orifice 15/16" Look here for the orifice identification Screw each LP orifice until orifice 23.8mm protrudes 15/16" (23.8mm) Front indicating full insertion (use Rear wrench to secure manifold when re-attaching orifice). Travis Industries 4140611 100-01387...
  • Page 60 Figure 2 Figure 1 Make the gas line connection, bleed the gas line (if applicable), start the heater and thoroughly leak-test all gas connections and the gas control valve. Travis Industries 4140611 100-01387...
  • Page 61: Fireback Installation

    - hold the rear fireback while installing the side fireback. 5/16" Nutdriver Place the side firebacks in place. Secure using the screws and clips removed in step "a". Place the floor firebacks in place. Travis Industries 4140611 100-01387...
  • Page 62: Grill Installation

    You will need to lift the grill slightly to get it over the get the tab over the bushing (this prevents it allows the grill to swing bushing. Once in place the grill is held in place by the grill from accidentally falling off). forward. gravity. Travis Industries 4140611 100-01387...
  • Page 63: Wiring Diagram

    3 Amp Fuse 3 Amp Fuse Appliance Ground 3.15A FUSE Integrated Pilot Sensor Fireplace Flame Control Detect (IFC) Spark System Jumper Appliance Ground IPI/CPI JUMPER WIRE Comfort Control Valve Black (4) AA Batteries Battery Box (Manual On/Off) Travis Industries 4140611 100-01387...
  • Page 64: Index

    Top Vent Configuration with Vertical Termination with Hor. Termination ........44 ..............33 Installation Options ..........6 Top Vent or Rear Vent Configuration ....9 Installation Overview .......... 7 Vent Requirements .......... 24 Log Set Installation ........... 51 Travis Industries 4140611 100-01387...