Optional Equipment
4. Attach the wiring and rheostat assembly following the directions below.
NOTE: You may need to cut or adjust some of the lock ties on the wiring harness.
NOTE: Make sure wiring does not contact blower impellers or any hot surfaces. Use lock-ties if
necessary.
Attach one black and
white wire to each
blower (orientation does
not matter).
Attach the wires labeled
SNAP DISC to the
snap disc (orientation
does not matter).
5. Turn on power to the fireplace.
NOTE: To test the blower without turning on the fireplace, use a jumper wire to connect the two
snap wires together (turn off power prior to connecting the jumper wire).
© Travis Industries
(for qualified installers only)
Plug the power cord into the
receptacle at the rear of the fireplace.
Attach the rheostat assembly to the
fireplace with the two black screws.
4050714
These wires are for the optional
remote control. Place them behind
the gas control valve.
100-01173_001