Sample Configuration Files - Sun Microsystems Sun Workstation 100U System Manager's Manual

Table of Contents

Advertisement

Building Sun Workstation Kernels
Rules for Defaulting System Devices
Appendix C. Sample Configuration Files
The following pages present several sample configuration files.
The following GENERIC configuration file is used to build the release kernel. Lines are inter-
preted in #comments#. Lines marked #mandatory# must be included in every configuration
file; lines which describe devices which your system does not have should be deleted when you
produce your system configuration file.
,
*
GENERIC SUN
*
machine
cpu
ident
time zone
max users
options
options
config
pseudo-device
pseudo-device
pseudo-device
pseudo-device
pseudo-device
pseudo- dev ice
pseudo-device
pseudo-device
pseudo-device
pseudo-device
pseudo-device
pseudo-device
controller
controller
controller
disk
disk
disk
disk
sun
"SVN2"
GENERIC
8 dst
2
INET
SYSACCT
, .. Mandatory •• "
I .. Mandatory .. "
" .. Mandatory.. If you use "GENERIC" as your system identifier, you may use
the "swap generic" clause in the "config" line below.
If
you customize the identifier
to
SYS_NAME,
you must either include an "options GENERIC" line or speciry at least
the device where your root file system lives in place or "swap generic". For
example, the "config" line ror a standard Sun 100U might read:
"config vmunix root on xy".#
# •• Mandatory •• Number and "dst" are variable,
1 ••
Mandatory •• Number may vary'
I .. Mandatory .. INET means include Internet code,
IOptional; include only with pseudo-device sysacct.
Controls inclusion or code to do process accounting - see
4Ut
(2) and
4ut
(5).:/1:
vmunix swap generic
I .. Mandatory.. Specify root and swap devices,
pty
bk
sysacct
inet
ether
loop
nd
win128
dtop4
ms3
kb3
IPseudo-tty's. Needed ror network or window system.,
IBerknet line discipline ror high speed tty input - see bk
(4).#
,Include only with SYSACCT options clause, above.#
# •• Mandatory.. Internet code - see inet
(4).,
IARP code. Must include ir using Ethernet - see
arp(4).#
I .. Mandatory .. Sortware loop back network device driver;
must include if INET - see
10(4).#
*Network disk. Needed ir server or diskless - see
nd(4).,
:f/:Window system. Number indicates max window::!. Must include dtop, below,
#Max Screens ('desktops'); required ror window system.#
IMax Mice; required ror window system - see
ml
(4).#
IMax Sun keyboards; required ir using any Sun keyboard;
omit ir using serial terminal ror console.'
ingres
*Ingres lock device,
mbO at nexus!
I .. Mandatory .. Multibus code.'
ipcO at mbO csr Ox40 priority 2
list
Interphase controller - see
ip(4).#
ipc1 at mbO esr Ox44 priority 2
ipO at ipcO drive 0
ip 1 at ipcO drive 1
ip2 at ipcl drive 0
ip3 at ipcl drive 1
12nd Interphase controller.
I
,,1st disk on 1st Interphase controller,
*2nd disk on 1st Interphase controller"
list
disk on 2nd Interphase controllerf
#2nd disk on 2nd Interphase controller,
7 January 1984
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sun workstation 150u

Table of Contents