Sun Microsystems Sun Workstation 100U System Manager's Manual page 285

Table of Contents

Advertisement

Sample Configuration Files
controller
controller
disk
disk
disk
disk
controller
disk
disk
tape
controller
disk
disk
tape
device
device
device
device
device
device
device
device
device
device
device
device
device
device
controller
controller
tape
tape
device
device
device
device
device
device
device
device
device
14
xycO at mbO csr Oxee40 priority 2
xyel at mbO csr Oxee48 priority 2
xyO at xycO drive 0
xyl at xycO drive 1
xy2 at xyc 1 drive 0
xy3 at xyc 1 drive 1
scO at mbO csr Ox80000 priority 2
sdO at seO drive 0 flags 0
sdl at scO drive 1 flags 0
stO at seO drive 32 flags I
sci at mbO csr Ox84000 priority 2
sd2 at sel drive 0 flags 0
sd3 at se I drive I flags 0
stl at se
I
drive 32 flags
I
ropcO at mbO csr Oxee0800 priority 1
skyO at mbO csr Ox2000 priority 2
zsO at mbO csr Oxeee800 flags 3 priority 2
zsl at mbO esr OxeecOOO flags 3 priority 2
zs2 at mbO csr Ox80800 flags 3 priority 2
zs3 at mbO esr Ox81000 flags 3 priority 2
zs4 at mbO csr Ox84800 flags 3 priority 2
zs5 at mbO csr Ox85000 flags 3 priority 2
octO at mbO csr Ox520 flags Oxff priority 4
mtiO at mbO csr Ox620 flags Oxff priority 4
ieO at mbO csr Ox88000 priority 3
ieO at mbO csr Ox8COOO flags 2 priority 3
ecO at mbO csr OxeOOOO priority 3
eel at mbO csr Oxe2000 priority 3
tmO at mbO esr OxaO priority 3
tm1 at mbO csr Oxa2 priority 3
mtO at tmO drive 0 flags
I
mt1 at tm1 drive 0 flags 1
arO at mbO csr Ox200 priority 3
ar1 at mbO csr Ox208 priority 3
cgoneO at mbO csr Oxe8000 priority 3
bwtwoO at mbO csr Ox700000 priority 3
bwoneO at mbO csr OxcOOOO priority 3
vpO at mbO csr Ox400 priority 2
vpcO at mbO csr Ox480 priority 2
vpcO at mbO csr Ox500 priority 2
piO at mbO csr Oxee2000 priority I
Building Sun Workstation Kernels
,1st Xylogics controller - see
ztI(4).#
12nd Xylogics controller#:
list disk on 1st Xylogics controllerl
,2nd disk on 1st Xylogics controllerl
,1st disk on 2nd Xylogics controller,
,2nd disk on 2nd Xylogics contrcllerf
lIst SCSI controller#
list
disk on 1st SCSI controller
I
12nd disk on 1st SCSI controller,
,SCSI tape#
'2nd SCSI controller,
,1st disk on 2nd SCSI controller,
#2nd disk on 2nd SCSI controller,
#SCSI tapef
I .. Mandatory .. Raster Op chip - see
rope (4).'
,Sky Floating Point board.,
,CPU ports - see
Z6
(4).'
,Sun-2 Video Board ports;
required if using Sun-2 keyboard and mouse.'
,1st SCSI Board ports.,
,1st SCSI Board ports.,
12nd SCSI Board ports.,
12nd SCSI Board ports.,
ICentral Data Octal Card - see
oct(4).'
ISystech terminal
MUX -
see
mti(4).,
list Sun-2 Ethernet Controller,
'2nd Sun-2 Ethernet Controller,
'1st 3COM Ethernet Controller - see
u(4)'
12nd 3COM Ethernet Controller,
lIst TAPEMASTER tape controller - see
tm(4).,
12nd T APEMASTER tape controller,
list
1/2" tape drive on 1st controller.,
list 1/2" tape drive on 2nd controller.,
list 1/4" tape drive - see
4r(4).'
12nd 1/4" tape drive.1
,1st Sun Color Board - see
tg(4)."
list monochrome Sun-2 monitor.,
,1st monochrome Sun-I monitor.'
IIkon Versatec Board - see
f1p(4).'
lIst Systech Centronics/Versatec Board - see
f1pe(4s).,
'2nd Systech Centronics/Versatec Board."
IParallel input. Only used on Sun Models 100U
a.nd 150U, for keyboard and mouse.
Not needed if using terminal for console.,
7 January 1984

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sun workstation 150u

Table of Contents