Enter network interface IP
Enter subnet mask
Enter default gateway IP
Please enter your ISO country code
Please enter your phone country code [1]:
Please enter your calling area code
Please enter your network SSID/Zone [
The system must be reset to function properly. Reboot? [yes/no]: y
Your new settings are displayed and the Access Gateway reboots. When the system
restarts, the Telnet interface is enabled (based on your new configuration settings which
are saved to the Access Gateway's on-board flash memory).
Start up configuration is now complete; however, before connecting the Access
Gateway to the customer's network, you must power down the system.
Go to
"Logging Out and Powering Down the System" on page
Logging Out and Powering Down the System
Use this procedure to log out and power down the Access Gateway.
Enter l (logout) at the Access Gateway Menu. Your serial session closes automatically.
1.
2.
Turn off the Access Gateway and disconnect the power cord.
Disconnect the serial cable between the Access Gateway and your computer.
3.
Connecting the Access Gateway to the Customer's Network
Use this procedure to connect the Access Gateway to the customer's network (after the start up
configuration parameters have been established).
Choose an appropriate physical location that allows a minimum clearance of 4cm either
1.
side of the unit (for adequate airflow).
2.
Connect the Access Gateway to the router, then connect the Access Gateway to the
customer's subscriber port.