Fieldbus PCI-Card

Setup

14.2.1 Status LEDs

No:
1
2
3
4
5
6
Fieldbus interface
Fig. 55 9-pin D-sub male layout
14.3 Setup
Node address setting can be in the range: 1-62 and 64-255.
Node address restrictions:
• Node address 0 is reserved for the fieldbus control system (e.g. the PLC)
• Node address 63 is reserved for configuration and diagnostic terminals
• Addresses 1 - 62 are used for connecting industrial peripheral devices to FIPIO. These devices
Page 64
Indication
Appl. connected
I/O ACCESS
Run
COM
Err
I/O
Meaning
State
Green
Controlled by application
Red
Standalone
Green, flashing
I/O access OK
Red, flashing
I/O access failure (recoverable)
Off
No activity
Off
Device not powered or major failure
(no communication)
Green
Normal operation (Device powered
up and operating)
Off
No bus activity
Green, flashing
Bus activity
Off
Not powered or device operating
normally
Red, flashing
Bus not connected or promptness
timeout
Red
Major unrecoverable fault
Off
Device operating normally
Red
External device error
Reg.No. ME00107EN-02